GARDEN CITY, NY —
OSHA Inspection: AVALON BAY COMMUNITIES INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AVALON BAY COMMUNITIES INC. in 1400 MITCHEL FEILD WAY, GARDEN CITY, NY 11530 (NAICS 531110). OSHA activity number 333319531.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AVALON BAY COMMUNITIES INC.
- Site address
- 1400 MITCHEL FEILD WAY
- City
- GARDEN CITY
- State
- NY
- ZIP
- 11530
- Mailing
- 671 N. GLEBE RD. SUITE 800, ARLINGTON, VA 22203
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 531110
- Employees
- 2700
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.24
- Issued
- Sep 27, 2012
- Abate by
- Oct 4, 2012
- Penalty
- Initial $5,000 · Current $5,000
General-duty citation text
29 CFR 1926.24: The employer did not develop and maintain an effective fire protection and prevention program at the jobsite throughout all phases of the construction, repair, alteration, or demolition work. a) Worksite - Employees were not provided with an effective fire protection and prevention program while constructing approximately 200 residential units; on or about 4/11/12. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (O) $5000
- — Z (S) $5000
1926.352 E
- Issued
- Sep 27, 2012
- Abate by
- Oct 4, 2012
- Penalty
- Initial $5,000 · Current $5,000
General-duty citation text
29 CFR 1926.352(e): Additional personnel was not assigned to guard against fire while the actual, welding, cutting, or heating operations were being performed, and for a sufficient period of time after completion of the work to ensure that no possibility of fire exists. a) Worksite, Interior - An employee used a torch to heat a copper pipe while assembling a shower body located in the bathroom wall. The employee was working alone; on or about 04/11/12. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (O) $5000
- — Z (S) $5000
1926.651 J02
- Issued
- Sep 27, 2012
- Abate by
- Sep 28, 2012
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. a) Worksite, Exterior - The spoil pile was placed on the edge of the excavation; on or about 04/19/12. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (O) $7000
- — Z (S) $7000
1926.651 K01
- Issued
- Sep 27, 2012
- Abate by
- Sep 28, 2012
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. a) Worksite, Exterior - Employees were in an unprotected excavation, there was no inspection by a competent person; on or about 04/19/12. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (O) $7000
- — Z (S) $7000
1926.652 A01
- Issued
- Sep 27, 2012
- Abate by
- Sep 28, 2012
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c) or 1926.652(b)(1)(i). a) Worksite, Exterior - Employees were working in an excavation approximately 8ft deep. The excavation had vertical walls and the employees were not protected from cave-ins by a protective system; on or about 04/19/12. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (O) $7000
- — Z (S) $7000
More inspections at Avalon BAY Communities INC.
View Avalon BAY Communities INC.'s full OSHA safety record →
More inspections in this industry (NAICS 531110)
More inspections in NY