ROCHESTER, NY ·
OSHA Inspection: ACAD DESIGN CORP.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ACAD DESIGN CORP. in 975 MT. READ BLVD., ROCHESTER, NY 14606 (NAICS 332710). OSHA activity number 333323228.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACAD DESIGN CORP.
- Site address
- 975 MT. READ BLVD.
- City
- ROCHESTER
- State
- NY
- ZIP
- 14606
- Mailing
- 975 MT. READ BLVD., ROCHESTER, NY 14606
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 8
- Ownership type
- Private (A)
Citations
9 citations on file for this inspection.
1910.37 A03
- Issued
- Apr 17, 2012
- Abate by
- May 17, 2012
- Penalty
- Initial $1,080 · Current $610 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level. a) On or about 4/13/12 in the surface grinder room; the south exit route door was blocked with a wooden pallet and a wooden pole was lodged against the door handle. Abatement Certification
Recent events (2)
- · I (S) $610
- · Z (S) $1080
1910.37 B02
- Issued
- Apr 17, 2012
- Abate by
- May 17, 2012
- Penalty
- Initial $1,080 · Current $0 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit must be clearly visible and marked by a sign reading "Exit." a) On or about 4/13/12 in the surface grinder room; the north exit near the time clock area was not marked.
Recent events (2)
- · I (S) $0
- · Z (S) $1080
1910.37 B05
- Issued
- Apr 17, 2012
- Abate by
- May 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit must be marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g., closet). a) On or about 4/13/12 in the surface grinder area; the double doors located on the east wall, leading to a storage area and other portions of the building, was not marked. Abatement Certification
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.212 A03 II
- Issued
- Apr 17, 2012
- Abate by
- May 17, 2012
- Penalty
- Initial $1,440 · Current $800 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards,shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operatingcycle. a) On or about 4/13/12 located in east side of the CNC machine area; the access door to the Mazak VTC-200B tooling area did not have an interlock which allowed access to the point of operation while the machine was operating. Abatement Certification
Recent events (2)
- · I (S) $800
- · Z (S) $1440
1910.252 B02 III
- Issued
- Apr 17, 2012
- Abate by
- May 17, 2012
- Penalty
- Initial $1,080 · Current $610 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: (a) On or about 4/13/12 in the southwest corner of the CNC area; a piece of 1/4" plywood ( approximately 24" x 36" ) was being placed between two magnetic stands on the welding table and used to protect employees during TIG welding operations. Abatement Certification
Recent events (2)
- · I (S) $610
- · Z (S) $1080
1910.303 B02
- Issued
- Apr 17, 2012
- Abate by
- May 17, 2012
- Penalty
- Initial $1,440 · Current $610 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. a) On or about 4/13/12 in the CNC machine room suspended above the Mazak CNC machine; a metal double-gang box with two light switches and two knock outs missing was being used to shut off the overhead lights and not properly installed. Abatement Certification
Recent events (2)
- · I (S) $610
- · Z (S) $1440
1910.305 B01 I
- Issued
- Apr 17, 2012
- Abate by
- May 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. a) On or about 4/13/12 on the south wall of the welding area in the CNC machine area; the conductors for the TIG welding machine ( 480 volts AC ) were exposed and not secured to the fitting on the junction box. b) On or about 4/13/12 on the back side of the Hass CNC machine; the conductors for line power coming into the electrical panel on the back side of the Hass machine were exposed and not secured to the fitting. Abatement Certification
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 G01
- Issued
- Apr 17, 2012
- Abate by
- May 17, 2012
- Penalty
- Initial $1,080 · Current $610 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment. a) On or about 4/13/12 in west side of the CNC machine area; access to the local electrical disconnect for the Mazak was blocked in two directions. Access from the east by a wooden pallet, hoses and five gallon pail and access from the south was blocked by five gallon pails stored along the west wall, a shelf filled with parts, and hoses and boxes of supplies. b) On about 4/13/12 behind the Hass CNC machine; access to the local electrical disconnect located on the north was was reduced to a width of 14" by one side of the machine and a building column. Abatement Certification
Recent events (2)
- · I (S) $610
- · Z (S) $1080
1910.1200 E01
- Issued
- Apr 17, 2012
- Abate by
- May 17, 2012
- Penalty
- Initial $1,080 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a)On or about throughout the facility; employees use hazardous chemicals, such as but not limited to, Mobil brand Air Compressor oil ( skin irritant ), oxygen ( flammable), cutting oils ( irritants ) without maintaining a written hazard communication program or providing training to employees on the hazards of these chemicals in their work area. Abatement Certification
Recent events (2)
- · I (S) $0
- · Z (S) $1080
More inspections at Acad Design Corp.
View Acad Design Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 333323228.