ACKERLY, TX ·
OSHA Inspection: ACME ENERGY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ACME ENERGY in 1.3 MILES SE DIRECTION FROM ACKERLY RIG #26, SMALLWOOD, WELL #1, ACKERLY, TX 79713 (NAICS 213112). OSHA activity number 333861821.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACME ENERGY
- Site address
- 1.3 MILES SE DIRECTION FROM ACKERLY RIG #26, SMALLWOOD, WELL #1
- City
- ACKERLY
- State
- TX
- ZIP
- 79713
- Mailing
- 7500 WEST HWY 80, MIDLAND, TX 79706
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 400
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.23 A09
- Issued
- Oct 5, 2012
- Abate by
- Oct 9, 2012
- Penalty
- Initial $3,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.23(a)(9): Every floor hole into which persons cannot accidentally walk (on account of fixed machinery, equipment, or walls) shall be protected by a cover that leaves no openings more than 1 inch wide. The cover shall be securely held in place to prevent tools or materials from falling through. Drilling Site: On or about April 11, 2012, an uncovered hole was found on Rig #26 on the elevated walking platform at Mud Pit #2 furthest from the drill.
Recent events (3)
- · J (S) $0
- · C (S) $3000
- · Z (S) $3000
1910.151 C
- Issued
- Oct 5, 2012
- Abate by
- Oct 9, 2012
- Penalty
- Initial $2,550 · Current $0 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use. Drilling Site: On or about April 11, 2012, a shower unit was discovered to not have water connected to the unit. The unit was located on the elevated work platform at the mud pit furthest from the drill. The hazard exposes employees to corrosive materials without the ability to quick drench or flush themselves off during emergency use.
Recent events (3)
- · J (S) $0
- · C (S) $2550
- · Z (S) $2550
More inspections at Acme Energy
View Acme Energy's full OSHA safety record →
More inspections in this industry (NAICS 213112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 333861821.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.