MIDDLETOWN, NY ·
OSHA Inspection: ST. THERESA'S NURSING AND REHABILITATION CENTER
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ST. THERESA'S NURSING AND REHABILITATION CENTER in 120 HIGHLAND AVENUE, MIDDLETOWN, NY 10940 (NAICS 623110). OSHA activity number 333863025.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ST. THERESA'S NURSING AND REHABILITATION CENTER
- Site address
- 120 HIGHLAND AVENUE
- City
- MIDDLETOWN
- State
- NY
- ZIP
- 10940
- Mailing
- 120 HIGHLAND AVENUE, MIDDLETOWN, NY 10940
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 623110
- Employees
- 123
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.37 A03
- Issued
- Sep 27, 2012
- Abate by
- Oct 27, 2012
- Penalty
- Initial $3,060 · Current $1,530 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes were not free and unobstructed. Materials or equipment were placed, either permanently or temporarily, within the exit route. a). On or about 4/12/12, in the boiler room, for employees that document boiler levels on a daily. The emergency exit door was blocked by a beam.
Recent events (2)
- · I (O) $1530
- · Z (S) $3060
1910.138 A
- Issued
- Sep 27, 2012
- Abate by
- Oct 27, 2012
- Penalty
- Initial $3,060 · Current $0 Reduced
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes: a). On or about 4/12/12, on site, for the employee that cleans the oven with Greasestrip Plus. The Greasestrip Plus contains sodium hydroxide. The employer did noit provide chemical resistant gloves.
Recent events (2)
- · I (S) $0
- · Z (S) $3060
1910.147 C01
- Issued
- Sep 27, 2012
- Abate by
- Oct 27, 2012
- Penalty
- Initial $3,825 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment would be isolated from the energy source and rendered inoperative: a). On or about 4/12/12, in the laundry room, for employees that change the belts on the washers. The employer did not provide and/or maintain a lock out/tag out program on site.
Recent events (2)
- · I (S) $0
- · Z (S) $3825
1910.151 C
- Issued
- Sep 27, 2012
- Abate by
- Oct 27, 2012
- Penalty
- Initial $3,060 · Current $0 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a). On or about 4/12/12, on site, for employees mixing 3 cups of Wax & Finish Remover with 3 gallons of water. The Wax & Finish Remover contains chemicals such as, but not limited to, ethanolamine (a corrosive). The employer did not provide an eye wash unit in the mixing vicinity. b). On or about 4/12/12, in the kitchen, for employees cleaning the oven with Greasestrip Plus Degreaser. The Greasestrip Plus contains sodium hydroxide. The employee sprays the degreaser onto the oven on a as needed basis. The employer did not provide an eye wash unit in the kitchen. c). On or about 4/12/12, in the laundry room, for the employees changing out the Emulsion Detergent for the washers. The Emulsion Detergent contains sodium hydroxide. The employer did not provide an eye wash unit in the laundry room.
Recent events (2)
- · I (S) $0
- · Z (S) $3060
1910.305 B01 II
- Issued
- Sep 27, 2012
- Abate by
- Oct 12, 2012
- Penalty
- Initial $3,825 · Current $1,913 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed: a). On or about 4/12/12, on site, in the electrical room, for employees that switch on/off the thermastat. The box had 2 missing knock outs.
Recent events (2)
- · I (O) $1912.5
- · Z (S) $3825
More inspections in this industry (NAICS 623110)