Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: AUFENBERG CHEVROLET

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AUFENBERG CHEVROLET in 830 MAPLE VALLEY LANE, FARMINGTON, MO 63640 (NAICS 441110). OSHA activity number 333868628.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Aufenberg Chevrolet for free Get an email when a new federal OSHA severe-injury report for Aufenberg Chevrolet is published. One employer, no account, unsubscribe in one click.
Establishment
AUFENBERG CHEVROLET
Site address
830 MAPLE VALLEY LANE
City
FARMINGTON
State
MO
ZIP
63640
Mailing
830 MAPLE VALLEY LANE, FARMINGTON, MO 63640
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441110
Employees
25
Ownership type
Private (A)

5 citations on file for this inspection.

1910.253 B02 II

Serious Gravity 5 1 instance 8 exposed
Issued
Apr 30, 2012
Abate by
May 3, 2012
Penalty
Initial $3,000 · Current $1,500 Reduced
29 CFR 1910.253(b)(2)(ii):     Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:  (a)(LOCATION)(IDENTIFY SPECIFIC OPERATIONS AND/OR CONDITIONS)(IDENTIFY SOURCE OF HEAT)      The compressed oxygen and acetylene cylinders stored in the tire change area were not stored in a manner to prevent accidental tipping or knock over.        Abatement certification and abatement documentation is required for this violation.  The documentation should include   written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • · I (S) $1500
  • · Z (S) $3000

1910.253 B02 IV

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 30, 2012
Abate by
May 3, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(iv):     Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:  (a)(LOCATION)(IDENTIFY SPECIFIC OPERATIONS AND/OR CONDITIONS)(PROVIDE MEASUREMENTS OF DISTANCE WHEN INVOLVED)      Cylinders stored in the tire change area were not stored with the protective caps in place.      Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.253 B04 I

Serious Gravity 10 2 instances 8 exposed
Issued
Apr 30, 2012
Abate by
May 3, 2012
Penalty
Initial $4,200 · Current $2,100 Reduced
29 CFR 1910.253(b)(4)(i):     Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire; or  (a) (LOCATION) (IDENTIFY SPECIFIC OPERATIONS AND/OR CONDITIONS)        In the tire change area the employer allowed the oxygen cylinder to be stored near a five gallon bucket of grease and also near the gasoline recovery tank.  both items were withing five feet of the stored cylnders with no divider between them.
Recent events (2)
  • · I (S) $2100
  • · Z (S) $4200

1910.305 B02 I

Deleted Serious Gravity 10 1 instance 8 exposed
Issued
Apr 30, 2012
Abate by
May 3, 2012
Penalty
Initial $4,200 · Current $0 Reduced
29 CFR 1910.305(b)(2)(i):     Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy        In the tire change area where a stand alone grinder was powered, the electrical outlet did not have a face cover where used by employees.        Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • · I (S) $0
  • · Z (S) $4200

1910.305 G01 IV A

Serious Gravity 10 1 instance 3 exposed
Issued
Apr 30, 2012
Penalty
Initial $4,200 · Current $2,100 Reduced
29 CFR 1910.305(g)(1)(iv)(A):     Flexible cords and cables were used as a substitute for the fixed wiring of a structure        In the maintenance area a flexible cord was used to power a light fixture.        Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • · I (S) $2100
  • · Z (S) $4200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 333868628.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.