PERRY, OK ·
OSHA Inspection: GARY MAY DRILLING INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GARY MAY DRILLING INC. in PIONEER AND CR 70 GPS N36.22.25 - W 97.21.04, PERRY, OK 73077 (NAICS 213111). OSHA activity number 333874220.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GARY MAY DRILLING INC.
- Site address
- PIONEER AND CR 70 GPS N36.22.25 - W 97.21.04
- City
- PERRY
- State
- OK
- ZIP
- 73077
- Mailing
- PO BOX 135, PERRY, OK 73077
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- Employees
- 5
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 5, 2012
- Abate by
- Sep 20, 2012
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a) Gary May Drilling Rig: On April 16, 2012 and at times prior there to, employee(s) were exposed falls by not being provided a safe means of alternate escape from the derrick board. The auxiliary emergency line was not installed.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1910.23 C01
- Issued
- Sep 5, 2012
- Abate by
- Sep 20, 2012
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard. a) Gary May Drilling Rig: On April 16, 2012 and at times prior there to, the employer failed to ensure that there was a standard railing on the platform between the dog house and stairs leading to the dog house.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1910.157 C01
- Issued
- Sep 5, 2012
- Abate by
- Sep 20, 2012
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) Gary May Drilling Rig: On April 16, 2012 and at times prior there to, the employer failed to ensure that there were fire extinguishers located and identifiable on the drilling rig.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1910.305 G02 II
- Issued
- Sep 5, 2012
- Abate by
- Sep 20, 2012
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: a) Gary May Drilling Rig: On April 16, 2012 and at times prior there to, the employer failed to ensure that flexible cords did not have splices or taps under the mud house.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1910.305 G02 III
- Issued
- Sep 5, 2012
- Abate by
- Sep 20, 2012
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a) Gary May Drilling Rig: On April 16, 2012 and at times prior there to, the employer failed to ensure that flexible cords going into an electrical panel were provided with adequate strain relief.