FORT LEWIS, WA —
OSHA Inspection: BLYTHE PLUMBING AND HEATING, INC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of BLYTHE PLUMBING AND HEATING, INC in WT ADMINISTRATION BLD. JACKSON AVE, FORT LEWIS, WA 98433 (NAICS 238220). OSHA activity number 333885846.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BLYTHE PLUMBING AND HEATING, INC
- Site address
- WT ADMINISTRATION BLD. JACKSON AVE
- City
- FORT LEWIS
- State
- WA
- ZIP
- 98433
- Mailing
- 2201 HUMBOLDT ST, BELLINGHAM, WA 98225
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.350 A01
- Issued
- May 3, 2012
- Abate by
- May 8, 2012
- Penalty
- Initial $2,142 · Current $2,142
General-duty citation text
29 CFR 1926.350(a)(1): Valve protection cap(s) were not in place on compressed gas cylinder(s): (a) Fort Lewis, Warrior In Transition Administration Building, Blythe trailer; Acetylene, oxygen and carbon dioxide compressed gas cylinders were in storage and did not have their valve protection caps on.
Recent events (2)
- — I (O) $2142
- — Z (S) $2142
1926.350 A10
- Issued
- May 3, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.350(a)(10): Oxygen cylinders in storage were not separated from fuel-gas cylinder or combustible materials (especially oil or grease), a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire-resistance rating of at least one-half hour. (a) Fort Lewis, Warrior In Transition Administration Building, Blythe trailer; Two oxygen compressed gas cylinders were stored with two acetylene compressed gas cylinders.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.350 A11
- Issued
- May 3, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.350(a)(11): Cylinders were not stored in definitely assigned storage places where the cylinders would not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: (a) Fort Lewis, Warrior InTransition Administration Building, Seven compressed gas cylinders were stored unsecured in the Blythe job trailer.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.403 I01 II
- Issued
- May 3, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(i)(1)(ii): Working space about electric equipment operating at 600 volts, nominal, or less was used for storage: (a) Fort Lewis, Warrior In Transition Administrative Building; An Easy Touch microwave and Sanyo refrigerator were stored underneath the breaker panel for the job trailer.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Blythe Plumbing and Heating, INC
View Blythe Plumbing and Heating, INC's full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in WA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 333885846.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.