MAGEE, MS ·
OSHA Inspection: POLKS MEAT PRODUCT
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of POLKS MEAT PRODUCT in 1801 SIMPSON HWY. 49, MAGEE, MS 39111 (NAICS 311611). OSHA activity number 333899847.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- POLKS MEAT PRODUCT
- Site address
- 1801 SIMPSON HWY. 49
- City
- MAGEE
- State
- MS
- ZIP
- 39111
- Mailing
- P.O.BOX 1190, MAGEE, MS 39111
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311611
- Employees
- 108
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Jun 11, 2012
- Abate by
- Jun 18, 2012
- Penalty
- Initial $2,754 · Current $1,652 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operatorand other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips andsparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. (a) On or about April 10, 2012 rotating shafts in the Wrap Room on Line 1, Line 2, and Line 4 were not guarded.
Recent events (2)
- · I (S) $1652.4
- · Z (S) $2754
1910.303 G02 I
- Issued
- Jun 11, 2012
- Penalty
- Initial $2,341 · Current $1,405 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidentalcontact by use of approved cabinets or other forms of approved enclosures or by any of the following means: (a) On or about April 10, 2012 In the Refrigrator Room a 480 volt panel box with open spaces was not effectively closed exposing employees to electrical shock.
Recent events (2)
- · I (S) $1404.6
- · Z (S) $2340.9
1910.305 G02 III
- Issued
- Jun 11, 2012
- Abate by
- Jun 12, 2012
- Penalty
- Initial $2,700 · Current $1,620 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws. (a) On or about April 10, 2012 the electrical wiring on the Thumbler was not continuous resulting in the strain release being broken exposing live wiring.
Recent events (2)
- · I (S) $1620
- · Z (S) $2700
More inspections in this industry (NAICS 311611)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 333899847.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.