NORTH JAVA, NY ·
OSHA Inspection: SELECT DOOR
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SELECT DOOR in 2074 PERRY ROAD, NORTH JAVA, NY 14113 (NAICS 321911). OSHA activity number 333913440.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SELECT DOOR
- Site address
- 2074 PERRY ROAD
- City
- NORTH JAVA
- State
- NY
- ZIP
- 14113
- Mailing
- 2074 PERRY ROAD, NORTH JAVA, NY 14113
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321911
- Employees
- 26
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.107 B09
- Issued
- Jun 22, 2012
- Penalty
- Initial $2,023 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction: a) On or about 04/18/12, in the spray booth area, wood doors were stored against the finishing spray booth's wall. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $1200
- · Z (S) $2023
1910.107 C06
- Issued
- Jun 22, 2012
- Abate by
- Jul 22, 2012
- Penalty
- Initial $2,380 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: a) On or about 04/18/12, in the finishing spray area, general purpose electrical switches for lighting and an exhaust fan, and an electrical receptacle were attached to finishing spray booth exterior walls. Distances from open-face booth edge to electrical wiring were less than 3 feet, there were approximately 3 inch, 6 inch and 12 inch respectively. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $1200
- · Z (S) $2380
1910.147 C04 I
- Issued
- Jun 22, 2012
- Abate by
- Jul 22, 2012
- Penalty
- Initial $2,975 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 04/18/12, in the production areas, Lockout/Tagout(LOTO) procedures were not utilized when employees changed blades, cutters, router bits and drill bits on machines such as, but not limited to: Delta Unisaw Table Saw, Griggio Table Saw, Raimann Weinig Group Rip Saw, Scmi SuperSet 23 Molder, Univer Martin Sharper, T130 Scmi Sharpers, Koch Rear End Cutter and Commander machine. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $1500
- · Z (S) $2975
1910.147 C06 I
- Issued
- Jun 22, 2012
- Penalty
- Initial $2,975 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 04/18/12, in the establishment, Employer did not perform periodic inspections of their specific lockout/tagout(LOTO) procedures for machines, such as, but not limited to: Delta Unisaw Table Saw, Griggio Table Saw, Raimann Weinig Group Rip Saw, Scmi SuperSet 23 Molder, Univer Martin Sharper, T130 Scmi Sharpers, Koch Rear End Cutter and Commander machine, with all their authorized employees. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $1500
- · Z (S) $2975
1910.178 L04 III
- Issued
- Jun 22, 2012
- Penalty
- Initial $1,785 · Current $1,300 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operators performance was not conducted at least once every 3 years: a) On or about 04/18/12, in the production areas, Employer did not evaluate the effectiveness of the training by observing forklift truck operators' driving skills/safe performance(e.g. road test/practical evaluation) in the workplace since 2006. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $1300
- · Z (S) $1785
1910.305 B01 I
- Issued
- Jun 22, 2012
- Abate by
- Jul 22, 2012
- Penalty
- Initial $1,785 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions: a) On or about 04/18/12, in the production area, a conductor entering a Delta Unisaw Table Saw's Cutout Box had exposed wires. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $0
- · Z (S) $1785
1910.305 B01 III
- Issued
- Jun 22, 2012
- Abate by
- Jul 22, 2012
- Penalty
- Initial $0 · Current $1,300
General-duty citation text
29 CFR 1910.305(b)(1)(iii): Cable was not secured to the cabinet, cutout box, or meter socket enclosure: a) On or about 04/18/12, in the production areas, a cable was not secured to a Delta Unisaw Table Saw's Cutout Box. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $1300
- · Z (S) $0
1910.95 G06
- Issued
- Jun 22, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels : a) On or about 04/18/12, in the establishment, the last audiometric examinations were performed on 04/05/2010. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 321911)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 333913440.