Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,473Inspections Most recent open 2026-07-28 Last loaded 2026-07-31

OSHA Inspection: SOUTH TEXAS STEEL SERVICE CO., LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SOUTH TEXAS STEEL SERVICE CO., LLC. in 226 E. TIDWELL, HOUSTON, TX 77022 (NAICS 332312). OSHA activity number 333930824.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch South Texas Steel Service CO., LLC. — free Get an email when a new federal OSHA severe-injury report for South Texas Steel Service CO., LLC. is published. One employer, no account, unsubscribe in one click.
Site address
226 E. TIDWELL
City
HOUSTON
State
TX
ZIP
77022
Mailing
226 E. TIDWELL, HOUSTON, TX 77022
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
8
Ownership type
A

2 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 5 exposed
Issued
Jun 1, 2012
Abate by
Jul 16, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  The employer does not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment is isolated from the energy source and rendered inoperative. This violation occurred on or about April 20, 2012, in the shop area where employees operated, serviced, and set-up bending machines and a shear machine to fabricate metal re-bar products and a hazardous energy program was not established.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.178 L02 II

Other-than-serious 1 instance 2 exposed
Issued
Jun 1, 2012
Abate by
Jun 15, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace.  The employer does not ensure that each operator had successfully completed the training consisting of a combination of formal instruction, practical training, and evaluation of the operator's performance in the workplace. This violation was observed on or about April 20, 2012, where an employee was allowed to operate Caterpillar and Hyster forklifts throughout the facility and the employees were not trained and evaluated by the employer.