Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: AREA ENERGY AND ELECTRIC INC

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of AREA ENERGY AND ELECTRIC INC in 8825 SMITH MILL ROAD NORTH, NEW ALBANY, OH 43054 (NAICS 238210). OSHA activity number 333932267.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Area Energy and Electric INC for free Get an email when a new federal OSHA severe-injury report for Area Energy and Electric INC is published. One employer, no account, unsubscribe in one click.
Site address
8825 SMITH MILL ROAD NORTH
City
NEW ALBANY
State
OH
ZIP
43054
Mailing
2001 COMMERCE DR., SIDNEY, OH 45365
Inspection type
Programmed Related (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
26
Ownership type
Private (A)

1 citation on file for this inspection.

1926.404 B01 III C

Serious Gravity 1 1 instance 10 exposed
Issued
May 21, 2012
Penalty
Initial $2,550 · Current $1,785 Reduced
29 CFR 1926.404(b)(1)(iii)(C):     Each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connectedby cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, shall be visually inspected before each day's use forexternal defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged ordefective shall not be used until repaired.    a. In the hallway outside the alcohol batch room, the employer failed to ensure that the ground prong was not missing from the pipe bender, therby exposing employees to a contact hazard.
Recent events (2)
  • · I (S) $1785
  • · Z (S) $2550

View Area Energy and Electric INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 333932267.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.