Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: ASRC ENERGY SERVICES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ASRC ENERGY SERVICES in LIBERTY ISLAND, PRUDHOE BAY, AK 99734 (NAICS 211111). OSHA activity number 333938447.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Asrc Energy Services for free Get an email when a new federal OSHA severe-injury report for Asrc Energy Services is published. One employer, no account, unsubscribe in one click.
Site address
LIBERTY ISLAND
City
PRUDHOE BAY
State
AK
ZIP
99734
Mailing
3900 C STREET SUITE 101, ANCHORAGE, AK 99503
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
211111
Employees
8
Ownership type
Private (A)

2 citations on file for this inspection.

1910.212 B

Deleted Serious Gravity 1 1 instance 8 exposed
Issued
Apr 30, 2012
Abate by
May 29, 2012
Penalty
Initial $2,250 · Current $0 Reduced
29 CFR 1910.212(b):     Anchoring fixed machinery. Machines designed for a fixed location shall be securely anchored to prevent walking or moving.    Workshop:  On or about 13 April 2012, and times prior thereto, stationary drill press was not secured to the floor; exposing employees to struck-by hazard.
Recent events (3)
  • · F (S) $0
  • · C (S) $2250
  • · Z (S) $2250

1910.305 G02 III

Deleted Other-than-serious 1 instance 6 exposed
Issued
Apr 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii):     Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.    Mud Room:  On or about 13 April 2012, and times prior there to, flexible cord used for temporary lighting had defective strain relief.  This exposed employees to electrical shock hazards.
Recent events (3)
  • · F (O) $0
  • · C (O) $0
  • · Z (O) $0

View Asrc Energy Services's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 333938447.