Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: AFC INDUSTRIES

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AFC INDUSTRIES in 13-16 133RD PLACE, FLUSHING, NY 11356 (NAICS 332322). OSHA activity number 333942027.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AFC Industries for free Get an email when a new federal OSHA severe-injury report for AFC Industries is published. One employer, no account, unsubscribe in one click.
Establishment
AFC INDUSTRIES
Site address
13-16 133RD PLACE
City
FLUSHING
State
NY
ZIP
11356
Mailing
13-16 133RD PLACE, FLUSHING, NY 11356
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
95
Ownership type
Private (A)

6 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 27, 2012
Abate by
Jul 5, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.23(c)(1):     Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides:    (a) Rear of Woodshop - The stoop directly outside the exit door had no railing.  The stoop led to stairs and exit discharge to the street; on or about 04/19/12.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1910.36 D01

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 27, 2012
Abate by
Jul 5, 2012
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.36(d)(1):     Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:    (a) Rear exit woodshop - Outside exit discharge to the street was locked; on or about 04/19/12.
Recent events (2)
  • · I (S) $1050
  • · Z (S) $2100

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 27, 2012
Abate by
Jul 5, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by, rotating parts:      (a) At the site - The cener lathe was not provided with a chuck guard; on or about 04/19/12.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 27, 2012
Abate by
Jul 5, 2012
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.212(a)(3)(ii):     Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    (a) At the worksite - A Doringer D-350 Saw was not properly guarded; on or about 04/19/12.
Recent events (2)
  • · I (S) $0
  • · Z (S) $3500

1910.212 A05

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 27, 2012
Abate by
Jul 5, 2012
Penalty
Initial $2,800 · Current $400 Reduced
29 CFR 1910.212(a)(5):     Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level:    (a) Welding area  A workstation fan did not have the back properly guarded; on or about 04/19/12.
Recent events (2)
  • · I (S) $400
  • · Z (S) $2800

1910.252 B02 III

Other-than-serious 3 instances 6 exposed
Issued
Jun 27, 2012
Abate by
Jul 5, 2012
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.252(b)(2)(iii):     Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:    (a) At the worksite - Not all welding workstations were enclosed by screens; on or about 04/19/2012.
Recent events (2)
  • · I (O) $0
  • · Z (S) $2100

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 333942027.