BUFFALO, NY ·
OSHA Inspection: SWEETWORKS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SWEETWORKS, INC. in 3500 GENESEE STREET, BUFFALO, NY 14225 (NAICS 311320). OSHA activity number 333945228.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SWEETWORKS, INC.
- Site address
- 3500 GENESEE STREET
- City
- BUFFALO
- State
- NY
- ZIP
- 14225
- Mailing
- 3500 GENESEE ST., BUFFALO, NY 14225
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311320
- Employees
- 300
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C06 I C
- Issued
- Jun 13, 2012
- Penalty
- Initial $5,000 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(C): Where lockout is used for energy control, the periodic inspection shall include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected. a) On or about 5/15/12 throughout the facility; energy control procedures, such as but not limited to, Metal Detector #573, #372 CCM Depositor, have not been reviewed with each authorized employee responsible to use the procedures. No Abatement Certification
Recent events (2)
- · I (S) $2500
- · Z (S) $5000
1910.147 C07 I A
- Issued
- Jun 13, 2012
- Penalty
- Initial $6,000 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. a) On or about 5/15/12 throughout the facility; Key Production Associates who perform the equipment cleaning, such as but not limited to, metal detectors, depositors, conveyors, were trained to the "Affected level". No Abatement Certification
Recent events (2)
- · I (S) $3000
- · Z (S) $6000
1910.147 D04 I
- Issued
- Jun 13, 2012
- Penalty
- Initial $6,000 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees. a) On or about 5/15/12 throughout the facility; Key Production Associates who perform equipment cleaning, such as but not limited to, metal detectors, depositors, conveyors, do not apply locks to the energy control devices during these service and maintenance activities. No Abatement Certification
Recent events (2)
- · I (S) $3000
- · Z (S) $6000
1910.147 F03 II D
- Issued
- Jun 13, 2012
- Penalty
- Initial $6,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee shall affix a personal lockout or tagout device to the group lockout device, group lockbox, or comparable mechanism when he or she begins work, and shall remove those devices when he or she stops working on the machine or equipment being serviced or maintained. a) On or about 5/15/12 on the Auxiliary Line; during the annual cleaning of the Auxiliary line a single locked was placed on the energy isolation device by the Mold Operator to provide protection against the unexpected start up of the equipment, for the two additional employees involved in cleaning this line. None of the other employees were required to affix a personal lock to each energy isolation device for the Auxiliary Line. No Abatement Certification
Recent events (2)
- · I (S) $0
- · Z (S) $6000
1910.212 A01
- Issued
- Jun 13, 2012
- Penalty
- Initial $3,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. a) On or about 5/15/12 in the South Maintenance shop; the exposed portion of the blade on the Horizontal band saw was not guarded. No Abatement Certification
Recent events (2)
- · I (S) $1500
- · Z (S) $3000
1910.303 B02
- Issued
- Jun 13, 2012
- Penalty
- Initial $3,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. a) On or about 5/15/12 on the Packing end of the Jensen Line; a relocatable power tap was secured with plastic ties to the frame of a conveyor and being used to provide power to the conveyor and scale. b) On or about 5/15/12 at the North Maintenance Shop; a relocatable power tap was on top of a tool cart and being used to recharge five portable power tool battery chargers. No Abatement Certification