OSHA Inspection: NORTHWEST ELECTRICAL CONTRACTORS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NORTHWEST ELECTRICAL CONTRACTORS, INC. in 1900 N. EAGLE RD., MERIDIAN, ID 83646 (NAICS 238210). OSHA activity number 333960623.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Northwest Electrical Contractors, INC. — free Get an email when a new federal OSHA severe-injury report for Northwest Electrical Contractors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1900 N. EAGLE RD.
City
MERIDIAN
State
ID
ZIP
83646
Mailing
1471 E. COMMERCIAL AVE, MERIDIAN, ID 83642
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
7
Ownership type
A

2 citations on file for this inspection.

1926.404 B01 III C

Other-than-serious 1 instance 7 exposed
Issued
May 4, 2012
Abate by
May 7, 2012
Penalty
Initial $2,023 · Current $500 Reduced
29 CFR 1926.404(b)(1)(iii)(C): Each cord set, attachment cap, plug, and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, were not visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged or defective was used prior to repair;    a)     Spider box on the second floor Northeast corner: On 4/17/2012, and at times prior thereto, employees were exposed to possible electric shock hazards when using power from a 208 volt 50 amp spider box that had a broken female cord cap receptacle.    Note: Abatement certification is required.
Recent events (2)
  • — I (O) $500
  • — Z (S) $2023

1926.416 E01

Other-than-serious Gravity 5 1 instance 7 exposed
Issued
May 4, 2012
Abate by
May 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:    a)  Spider box on the second floor Northeast corner: On 4/17/2012, and at times prior thereto, employees using cord and plug powered tools energized from the spider box were exposed to possible electrical shock hazard because the power supply cord (baloney cord) was pulled loose disrupting power to the box.    Note: Abatement certification is required.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

View Northwest Electrical Contractors, INC.'s full OSHA safety record →