MAYNARD, MA ·
OSHA Inspection: EINSTEIN SOLUTIONS, INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of EINSTEIN SOLUTIONS, INC in DEERPATH, MAYNARD, MA 01754 (NAICS 238170). OSHA activity number 333965622.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EINSTEIN SOLUTIONS, INC
- Site address
- DEERPATH
- City
- MAYNARD
- State
- MA
- ZIP
- 01754
- Mailing
- 11 SUMMIT STREET, FITCHBURG, MA 01420
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 6
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.404 B01 I
- Issued
- May 15, 2012
- Penalty
- Initial $4,200 · Current $2,900 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified inparagraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section toprotect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors. Location - Deerpath, Maynard, Ma: Clubhouse On or about 3/28/2012, an employee was using power tools that were not protected by a ground fault circuit interrupter.
Recent events (2)
- · I (S) $2900
- · Z (S) $4200
1926.404 F06
- Issued
- May 15, 2012
- Penalty
- Initial $4,200 · Current $2,900 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent andcontinuous. Location - Deerpath, Maynard, Ma: Clubhouse On or about 3/28/2012, an employee was using an extension cord that did not have a ground prong.
Recent events (2)
- · I (S) $2900
- · Z (S) $4200
1926.451 B05 II
- Issued
- May 15, 2012
- Penalty
- Initial $3,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(b)(5)(ii): Each platform greater than 10 feet in length shall not extend over its support more than 18inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, orhas guardrails which block employee access to the cantilevered end. Location - Deerpath, Maynard, Ma: Clubhouse On or about 3/28/2012, an employee was workilng from a pumpjack scaffold platform that was greater than ten feet in length, the platform extended over its support greater than 18 inches.
Recent events (2)
- · I (S) $0
- · Z (S) $3000
1926.451 F15
- Issued
- May 15, 2012
- Penalty
- Initial $3,000 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.451(f)(15): Ladders shall not be used on scaffolds to increase the working level height of employees, except onlarge area scaffolds where employers have satisfied the following criteria: Location - Deerpath, Maynard, Ma: Clubhouse On or about 3/28/2012, an employee working from a pumpjack scaffold was using a step ladder to increase the employees working height.
Recent events (2)
- · I (S) $2100
- · Z (S) $3000
1926.1053 B04
- Issued
- May 15, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders shall be used only for the purpose for which they were designed. Location - Deerpath, Maynard, Ma: Clubhouse On or about 3/28/2012, an employee working from a pumpjack scaffold was using a step ladder in the closed position to elevate the employees working height.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.451 G04 I
- Issued
- May 15, 2012
- Penalty
- Initial $3,000 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems shall be installed along all open sides and ends of platforms. Guardrailsystems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews. Location - Deerpath, Maynard, Ma: Clubhouse On or about 3/28/2012, an employee working from a pumpjack scaffold was not protected on all sides of the scaffold platform.
Recent events (2)
- · I (S) $2100
- · Z (S) $3000
1926.452 J02
- Issued
- May 15, 2012
- Penalty
- Initial $3,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom,top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled. Location - Deerpath, Maynard, Ma: Clubhouse On or about 3/28/2012, an employee working from a pumpjack scaffold that was not secured at the bottom to prevent unintentional displacement.
Recent events (2)
- · I (S) $0
- · Z (S) $3000
More inspections in this industry (NAICS 238170)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 333965622.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.