ORCHARD PARK, NY ·
OSHA Inspection: TORRENT EMS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TORRENT EMS in 4 CENTER DRIVE, ORCHARD PARK, NY 14127 (NAICS 333992). OSHA activity number 333986420.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TORRENT EMS
- Site address
- 4 CENTER DRIVE
- City
- ORCHARD PARK
- State
- NY
- ZIP
- 14127
- Mailing
- 4 CENTER DRIVE, ORCHARD PARK, NY 14127
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333992
- Employees
- 23
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.157 C01
- Issued
- Jun 11, 2012
- Penalty
- Initial $867 · Current $867
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) On or about 04/25/12, in the production areas, access to a fire extinguisher was blocked by pallets and a box with parts. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- · Z (S) $867
1910.157 E02
- Issued
- Jun 11, 2012
- Abate by
- Jul 11, 2012
- Penalty
- Initial $1,020 · Current $1,020
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: a) On or about 04/25/12, in the establishment, fire extinguishers were not inspected monthly. Last fire extinguishers inspections were performed on 2007. ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- · Z (S) $1020
1910.157 E03
- Issued
- Jun 11, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: a) On or about 04/25/12, in the establishment, employer did not perform annual maintenance checks on their fire extinguishers. Last fire extinguishers maintenance checks were done on 2007 by Elwood Fire Protection. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- · Z (S) $0
1910.303 B02
- Issued
- Jun 11, 2012
- Abate by
- Jul 11, 2012
- Penalty
- Initial $1,020 · Current $1,020
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) On or about 04/25/12, in the production/soldering areas, a 15 Amp power tap attached to a workstation was series connected (daisy chained) to other power tap located at another workstation. These power taps were used to energize equipment such as, but not limited to: soldering iron, light fixtures, microscopes, radios, heaters and soldering stations. ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- · Z (S) $1020
1910.1200 E01
- Issued
- Jun 11, 2012
- Abate by
- Jul 11, 2012
- Penalty
- Initial $1,360 · Current $1,360
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) On or about 04/25/12, in the establishment, Employer did not develop and implement a written hazard communication program. Employees used and handled chemicals such as, but not limited to: Compressed Nitrogen Gas, Nitrogen Refrigerated Liquid, UN1977, and Soldering Products. ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- · Z (S) $1360
1910.1200 G01
- Issued
- Jun 11, 2012
- Abate by
- Jul 11, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use: a) On or about 04/25/12, in the establishment, Employer did not have a Material Safety Data Sheet (MSDS) for Nitrogen Refrigerated Liquid, UN 1977. ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- · Z (S) $0
1910.1200 H01
- Issued
- Jun 11, 2012
- Abate by
- Jul 11, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employers did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees had not previously been trained about was introduced into their work area and chemical-specific information was not always available through labels and material safety data sheets: a) On or about 04/25/12, in the establishment, Employer did not provide training about their hazard communication program and the hazards associated with handling and using chemicals such as, but not limited to: Compressed Nitrogen Gas, Nitrogen Refrigerated Liquid, UN1977 and Soldering Products. ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- · Z (S) $0
More inspections at Torrent EMS
View Torrent EMS's full OSHA safety record →
More inspections in this industry (NAICS 333992)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 333986420.