Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: STATEWIDE FENCE BUILDERS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of STATEWIDE FENCE BUILDERS, INC. in 53 HARRINGTON AVENUE, WARWICK, RI 02888 (NAICS 238990). OSHA activity number 333991826.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Statewide Fence Builders, INC. for free Get an email when a new federal OSHA severe-injury report for Statewide Fence Builders, INC. is published. One employer, no account, unsubscribe in one click.
Site address
53 HARRINGTON AVENUE
City
WARWICK
State
RI
ZIP
02888
Mailing
1763 ELMWOOD AVENUE, WARWICK, RI 02888
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
24
Ownership type
Private (A)

8 citations on file for this inspection.

1910.178 A05

Other-than-serious 1 instance 4 exposed
Issued
May 23, 2012
Abate by
Jun 14, 2012
Penalty
Initial $2,550 · Current $0 Reduced
29 CFR 1910.178(a)(5):     If the truck is equipped with front-end attachments other than factory installed attachments, the user shall request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered.        Located at Statewide Fence Builders, Inc., Warwick, RI, Yard: On or about 03/30/2012 the Nissan 60 forklift was being used with fork extensions whereby the employer did not have a data plate to reflect the adjusted capacity information.
Recent events (2)
  • · I (O) $0
  • · Z (S) $2550

1910.178 A06

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
May 23, 2012
Abate by
Jun 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(6):     The user shall see that all nameplates and markings are in place and are maintained in a legible condition.    Located at Statewide Fence Builders, Inc., Warwick, RI, Yard: On or about 03/30/2012 the Nissan 60 forklift was being operated whereby the forklift did not have a data plate installed to reflect the vehicles lifting capacity.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 L01 I

Serious Gravity 5 1 instance 2 exposed
Issued
May 23, 2012
Abate by
Jun 14, 2012
Penalty
Initial $2,550 · Current $1,275 Reduced
29 CFR 1910.178(l)(1)(i):     The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).    Located at Statewide Fence Builders, Inc., Warwick, RI: On or about 03/30/2012 the employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).
Recent events (2)
  • · I (S) $1275
  • · Z (S) $2550

1910.178 L02 II

Serious Gravity 5 1 instance 2 exposed
Issued
May 23, 2012
Abate by
Jun 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(2)(ii):     Training shall consist of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace.    Located at Statewide Fence Builders, Inc. Warwick, RI: On or about 03/30/2012 the employer's forklift training program did not include practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 L04 III

Serious Gravity 5 1 instance 4 exposed
Issued
May 23, 2012
Abate by
Jun 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii):     An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years.    Located at Statewide Fence Builders, Inc., Warwick RI: On or about 03/30/2012 an evaluation of each powered industrial truck operator's performance was not conducted at least once every three years.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 L06

Serious Gravity 1 2 instances 2 exposed
Issued
May 23, 2012
Abate by
Jun 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6):     Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.    Located at Statewide Fence Builders, Inc., Warwick, RI: On or about 03/30/2012 the employer did not certify that each operator has been trained and evaluated as required by this paragraph in that two powered industrial truck operators did not have certification of training as required by this standard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.213 G01

Serious Gravity 5 1 instance 2 exposed
Issued
May 23, 2012
Abate by
Jul 6, 2012
Penalty
Initial $2,550 · Current $1,275 Reduced
29 CFR 1910.213(g)(1):     Each swing cutoff saw shall be provided with a hood that will completely enclose the upper half ofthe saw, the arbor end, and the point of operation at all positions of the saw. The hood shall be constructed in such a manner and of such materialthat it will protect the operator from flying splinters and broken saw teeth. Its hood shall be so designed that it will automatically cover the lowerportion of the blade, so that when the saw is returned to the back of the table the hood will rise on top of the fence, and when the saw is movedforward the hood will drop on top of and remain in contact with the table or material being cut.    Located at Statewide Fence Builders, Inc., Warwick, RI, Mill Building: On or about 03/30/2012 the Reynolds swing cutoff saw (Model T8836) did not have a hood installed.
Recent events (2)
  • · I (S) $1275
  • · Z (S) $2550

1910.178 Q07

Deleted Other-than-serious 1 instance 4 exposed
Issued
May 23, 2012
Abate by
May 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(7):     Industrial trucks shall be examined before being placed in service, and shall not be placed in service if the examination shows any condition adversely affecting the safety of the vehicle. Such examination shall be made at least daily. Where industrial trucks are used on a round-the-clock basis, they shall be examined after each shift. Defects when found shall be immediately reported and corrected.    Located at Statewide Fence Builders, Inc., Warwick, RI: On or about 03/30/2012 the Nissan and Clark forklifts were being operated without being examined before being placed in service.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Statewide Fence Builders, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 333991826.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.