Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ELLISON PLUMBING & PIPING, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of ELLISON PLUMBING & PIPING, INC. in PARK STREET, ORONO, ME 04473 (NAICS 238220). OSHA activity number 334009024.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ellison Plumbing & Piping, INC. — free Get an email when a new federal OSHA severe-injury report for Ellison Plumbing & Piping, INC. is published. One employer, no account, unsubscribe in one click.
Site address
PARK STREET
City
ORONO
State
ME
ZIP
04473
Mailing
4360 DAWES LANE EAST, MOBILE, AL 36619
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
7
Ownership type
A

4 citations on file for this inspection.

1926.404 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 19, 2012
Abate by
Jun 22, 2012
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.404(b)(1)(i):     The employer shall use either ground fault circuit interrupters (GFCI) as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.    Orono Student Apartments - The Honeywell generator, supplying power to the saw and drill, was not provided with a GFCI.
Recent events (1)
  • — Z (S) $2000

1926.404 F06

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 19, 2012
Abate by
Jun 22, 2012
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.404(f)(6):     Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.    Orono Student Apartments - The ground pin on the yellow extension cord was broken.
Recent events (1)
  • — Z (S) $2800

1926.405 G02 IV

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 19, 2012
Abate by
Jun 22, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv):     Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.    Orono Student Apartments - The yellow extension cord was not provided with strain relief.
Recent events (1)
  • — Z (S) $0

1926.405 A02 II I

Other-than-serious 2 instances 2 exposed
Issued
Jun 19, 2012
Abate by
Jun 22, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(I):     Flexible cords and cables shall be protected from damage.    Orono Student Apartments - The three extension cords were not protected from vehicular damage.
Recent events (1)
  • — Z (O) $0

View Ellison Plumbing & Piping, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334009024.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.