THOMPSON FALLS, MT —
OSHA Inspection: UNITED STATES ANTIMONY CORPORATION
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of UNITED STATES ANTIMONY CORPORATION in 1250 PROSPECT CREEK RD, THOMPSON FALLS, MT 59873 (NAICS 331419). OSHA activity number 334031424.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNITED STATES ANTIMONY CORPORATION
- Site address
- 1250 PROSPECT CREEK RD
- City
- THOMPSON FALLS
- State
- MT
- ZIP
- 59873
- Mailing
- P.O. BOX 643, THOMPSON FALLS, MT 59873
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331419
- Employees
- 15
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.23 A02
- Issued
- Oct 1, 2012
- Abate by
- Oct 9, 2012
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.23(a)(2): Ladderway floor opening(s) or platform(s) were not guarded by a standard railing with standard toeboard(s) on all exposed sides (except at the entrance to opening) with the passage through the railing either provided with a swinging gate or so offset that a person cannot walk directly into the opening: (a) On April 18, 2012 and at times prior thereto, employees were exposed to a fall from height of approximately 14 feet while doing maintenance on the fan platforms without a swinging gate or an offset barrier to prevent a person from walking into the unprotected opening.
Recent events (2)
- — I (S) $1600
- — Z (S) $1600
1910.151 C
- Issued
- Oct 1, 2012
- Abate by
- Oct 9, 2012
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) On April 18, 2012 and at times prior thereto, employees were exposed to eye damage while stacking or moving corrosive products such as but not limited to Sodium Antimony Compounds with a ph value of 13 without an adequate eyewash station readily available.
Recent events (2)
- — I (S) $1600
- — Z (S) $1600
1910.212 A01
- Issued
- Oct 1, 2012
- Abate by
- Oct 9, 2012
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) On April 18, 2012 and at times prior thereto, employees were exposed to caught by hazards from an unguarded conveyor belt while batch mixing antimony products.
Recent events (2)
- — I (S) $1600
- — Z (S) $1600
1910.253 B04 I
- Issued
- Oct 1, 2012
- Abate by
- Oct 9, 2012
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire: (a) On or about April 18, 2012 and at times prior thereto, employees were exposed to fire and/or explosion hazards due to storing oxygen cylinders beside acetylene cylinders and propane bottles.
Recent events (2)
- — I (S) $1600
- — Z (S) $1600
1910.305 B01 I
- Issued
- Oct 1, 2012
- Abate by
- Oct 9, 2012
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions: (a) On April 18, 2012 and at times prior thereto, employees were exposed to electrical shock hazards due to the outer sheathing of an electrical cord that was broken and exposed internal wires from an electrical box in the bag house.
Recent events (2)
- — I (S) $2000
- — Z (S) $2000
1910.303 B02
- Issued
- Oct 1, 2012
- Abate by
- Oct 9, 2012
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) On or about April 18, 2012 and at times prior thereto, employees were exposed to electrical shock hazards while working in the lab due to a relocatable power strip used as a permanent wiring fixture.
Recent events (2)
- — I (S) $1200
- — Z (S) $1200
1910.305 G01 IV D
- Issued
- Oct 1, 2012
- Abate by
- Oct 9, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were attached to building surfaces: (a) On April 18, 2012 and at times prior thereto, employees were exposed to electrical shock hazards due to an orange extension cord securely attached to the ceiling in place of permanent electrical wiring.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at United States Antimony Corporation
View United States Antimony Corporation's full OSHA safety record →
More inspections in this industry (NAICS 331419)
More inspections in MT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334031424.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.