SEABROOK, TX —
OSHA Inspection: DYNAMIC DEVELOPER INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DYNAMIC DEVELOPER INC. in 204 NELSON, SEABROOK, TX 77586 (NAICS 238990). OSHA activity number 334040052.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DYNAMIC DEVELOPER INC.
- Site address
- 204 NELSON
- City
- SEABROOK
- State
- TX
- ZIP
- 77586
- Mailing
- 3301 NELSON, SEABROOK, TX 77586
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 12
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.403 B02
- Issued
- Jun 22, 2012
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: On April 25, 2012, at 204 Nelson, Seabrook, TX, employees were exposed to electrical hazards when using a modified extension cord to activate a drill and circular saw.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.501 B13
- Issued
- Jun 22, 2012
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b) Note: If using these systems was infeasible or created a greater hazard, the employer should develop and implement a fall protection plan meeting the requirements of paragraph (k) of 1926.502. On April 25, 2012, at 204 Nelson, Seabrook, TX, employees are exposed to fall hazards while installing rain gutters on a roof with a 4/12 pitch at a height greater than 6 feet.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.1053 B01
- Issued
- Jun 22, 2012
- Penalty
- Initial $1,360 · Current $680 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: On April 25, 2012, at 204 Nelson, Seabrook, TX, employees were exposed to falls from elevation when using a ladder to access the upper landing.
Recent events (2)
- — I (S) $680
- — Z (S) $1360
More inspections in this industry (NAICS 238990)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334040052.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.