CHICAGO, IL —
OSHA Inspection: TRITON INDUSTRIES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TRITON INDUSTRIES, INC. in 1020 NORTH KOLMAR AVE., CHICAGO, IL 60651 (NAICS 332999). OSHA activity number 334064029.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRITON INDUSTRIES, INC.
- Site address
- 1020 NORTH KOLMAR AVE.
- City
- CHICAGO
- State
- IL
- ZIP
- 60651
- Mailing
- 1020 NORTH KOLMAR AVE., CHICAGO, IL 60651
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 38
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Sep 27, 2012
- Abate by
- Nov 19, 2012
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation: a. Truck Sign Room - On or about April 24, 2012, employees were required to operate the following rivet machines without guards: 1. National Rivet & Mfg. Co. 2. Chicago Rivet & Machine Co. Employees were thereby exposed to pinch point hazards from moving parts.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.217 C03 III F
- Issued
- Sep 27, 2012
- Abate by
- Nov 19, 2012
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.217(c)(3)(iii)(f): Mechanical power press(es) using presence sensing point of operation devices were not provided with guards to protect all areas of entry to the point of operation not protected by the presence sensing device(s) a. Truck Sign Room - On or about April 24, 2012, the following part revolution mechanical power presses were not completely guarded, thereby exposing employees to crushing hazards: 1. Minster #913 2. Verson #261
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.147 C06 II
- Issued
- Sep 27, 2012
- Abate by
- Nov 9, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection. a. Entire facility - On or about April 24, 2012, the employer had not adequately certified periodic inspections of the established energy control procedures in place for employees who perform servicing and maintenance of equipment. Employees were thereby exposed to the hazards associated with the unexpected energization of equipment.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Triton Industries, INC.
View Triton Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334064029.