Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: FUNK LINKO, INC.

Special Programs inspection · Safety discipline

On , OSHA opened a special Programs safety inspection of FUNK LINKO, INC. in 1633 5TH AVENUE, CHICAGO HEIGHTS, IL 60411 (NAICS 333518). OSHA activity number 334068020.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Funk Linko, INC. for free Get an email when a new federal OSHA severe-injury report for Funk Linko, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
FUNK LINKO, INC.
Site address
1633 5TH AVENUE
City
CHICAGO HEIGHTS
State
IL
ZIP
60411
Mailing
1633 5TH AVENUE, CHICAGO HEIGHTS, IL 60411
Inspection type
Special Programs (K)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333518
Employees
28
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 12 exposed
Issued
Jul 26, 2012
Abate by
Aug 31, 2012
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.147(c)(4)(i):     Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.     Production area - On or about April 27, 2012,  the written program did not include specific procedures for locking out all energy sources on the Amada press brakes, Baykel shear, Marvel metal cutting bandsaw, and other operating equipment.
Recent events (2)
  • · I (S) $1750
  • · Z (S) $3500

1910.147 C06 I

Serious Gravity 5 1 instance 12 exposed
Issued
Jul 26, 2012
Abate by
Aug 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i):     The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.    Production area - On or about April 27, 2012, certication was not available to show that periodic inspection of the energy control procedures had not been performed at least annually.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.253 B02 II

Serious Gravity 5 5 instances 20 exposed
Issued
Jul 26, 2012
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.253(b)(2)(ii):     Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 (6.1 m) feet from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards.    Production area - On or about April 27, 2012, the following cylinders were not in a secured enclosure, thereby exposing employees to the hazard of an explosion.    1. one argon   2. one oxygen  3. three propane
Recent events (2)
  • · I (S) $1750
  • · Z (S) $3500

1910.253 B04 III

Serious Gravity 5 1 instance 12 exposed
Issued
Jul 26, 2012
Abate by
Aug 9, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii):     Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.    Production area/northeast - On or about April 14, 2012, oxygen,argon and propane cylinders in storage were not separated by the minumum distance of 20 feet, thereby exposing employees tothe hazardss of fire and explosion.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334068020.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.