PORTERVILLE, CA —
OSHA Inspection: EAGLE MOUNTAIN CASINO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EAGLE MOUNTAIN CASINO in 681 S. RESERVATION ROAD, PORTERVILLE, CA 93257 (NAICS 722110). OSHA activity number 334070422.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EAGLE MOUNTAIN CASINO
- Site address
- 681 S. RESERVATION ROAD
- City
- PORTERVILLE
- State
- CA
- ZIP
- 93257
- Mailing
- P.O BOX 1659, PORTERVILLE, CA 93258
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 722110
- Employees
- 450
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.215 B09
- Issued
- May 11, 2012
- Abate by
- May 16, 2012
- Penalty
- Initial $2,250 · Current $1,575 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): Safety guards of the types described in Subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, were not constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b)(3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch: (a) In the shop on or about April 27, 2012, and at times prior thereto, the tongue guards were not within one quarter inch both abrasive wheels on a Porter Cable bench grider, model number PC 857586, serial number 020769. The tongue guards were about one half inch from the wheels. The grinder was used to sharpen chisels and metal parts.
Recent events (2)
- — I (S) $1575
- — Z (S) $2250
1910.212 B
- Issued
- May 11, 2012
- Abate by
- May 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machines designed for a fixed location were not securely anchored to prevent walking or moving: (a) In the shop on or about April 27, 2012, and at times prior thereto, a Delta 8 inch drill press was not secured to the table. There were holes in the drill press base to mount it to a surface. The drill press was used to drill holes in metal for new slot machine bases. There were metal shavings on the table.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.244 A01 II
- Issued
- May 11, 2012
- Abate by
- May 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.244(a)(1)(ii): The rated load was not legibly and permanently marked in a prominent location on the jack by casting, stamping, or other suitable means: (a) In the shop on or about April 27, 2012, and at times prior thereto, there was no label or marking on a vehicle jack that indicated the capacity of the jack.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B02
- Issued
- May 11, 2012
- Abate by
- May 16, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. (a) In the shop on or about April 27, 2012, and at times prior thereto, a 110 VAC Delta 8 inch drill press was powered through a surge bar designed to power electronic equipment such as computers, radios, and televisions.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Eagle Mountain Casino
View Eagle Mountain Casino's full OSHA safety record →
More inspections in this industry (NAICS 722110)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334070422.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.