Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: QUALITY DESIGN NOR'EASTER SWIMMING POOLS, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of QUALITY DESIGN NOR'EASTER SWIMMING POOLS, INC in 1 HIGHLANDER WAY, MANCHESTER, NH 03101 (NAICS 238990). OSHA activity number 334093424.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quality Design Nor'Easter Swimming Pools, INC for free Get an email when a new federal OSHA severe-injury report for Quality Design Nor'Easter Swimming Pools, INC is published. One employer, no account, unsubscribe in one click.
Site address
1 HIGHLANDER WAY
City
MANCHESTER
State
NH
ZIP
03101
Mailing
13 COLUMBIA DRIVE UNIT 28, AMHERST, NH 03031
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
3
Ownership type
Private (A)

6 citations on file for this inspection.

1926.451 A06

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 25, 2012
Abate by
Sep 26, 2012
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1926.451(a)(6): Scaffolds were not designed by a qualified person:    a. Pool- Employees working from a top plate bracket scaffold which was supported by the top of the pool wall were exposed to fall hazards where a qualified person did not design the scaffold.
Recent events (2)
  • · I (S) $600
  • · Z (S) $1200

1926.451 B02 I

Serious 1 instance 2 exposed
Issued
Sep 25, 2012
Abate by
Sep 26, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(2)(i): Each ladder jack scaffold, top plate bracket scaffold, roof bracket scaffold, and pump jack scaffold was not at least 12 inches (30 cm) wide:    a. Pool- Employees working from a top plate bracket scaffold which was supported by the top of the pool wall were exposed to a fall hazard where a single row of 2x10 inch wood planking was used as a work platform.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 B07

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 25, 2012
Abate by
Sep 26, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(7): On scaffolds where platforms were overlapped to create a long platform, the overlap did not occur only over supports, and/or was less than 12 inches (30 cm) when the platforms were not nailed together or otherwise restrained to prevent movement:    a. Pool- Employees working from a top plate bracket scaffold which was supported by the top of the pool wall were exposed to a fall hazard where a single row of 2x10 inch wood planking was used as a work platform and the overlaps between planks were less than 12 inches in length and not all of the overlaps did not occur over the supports.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.501 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 25, 2012
Abate by
Sep 26, 2012
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.      a. Pool Deck- Employees were exposed to a fall of approximately 7 feet while working around the edges of an in ground pool under construction where fall protection was not used or provided.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1926.403 B02

Other-than-serious 1 instance 2 exposed
Issued
Sep 25, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:      a. Site- A relocatable power tap meant for indoor use only was used to provide power for a Milwaukee cordless drill battery charger. The relocatable power tap was protected by a ground fault circuit interrupter.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1926.405 G02 IV

Other-than-serious 1 instance 2 exposed
Issued
Sep 25, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:    a. Site- An extension cord missing strain relief was used to provide power for a Milwaukee cordless drill battery charger. The extension cord was protected by a ground fault circuit interrupter.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334093424.