Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STEELCAD INDUSTRIAL SERVICES, INC.

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of STEELCAD INDUSTRIAL SERVICES, INC. in 1270 JAMESTOWN RD, CUTLER, IL 62238 (NAICS 332312). OSHA activity number 334097029.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Steelcad Industrial Services, INC. — free Get an email when a new federal OSHA severe-injury report for Steelcad Industrial Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1270 JAMESTOWN RD
City
CUTLER
State
IL
ZIP
62238
Mailing
1270 JAMESTOWN RD, CUTLER, IL 62238
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
20
Ownership type
A

9 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 5 exposed
Issued
Nov 27, 2012
Abate by
Dec 30, 2012
Penalty
Initial $400 · Current $400
29 CFR 1903.19(c)(1):     The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:    For Citation 3, Item 1, issued on 10/19/2012 with an abatement date of 10/26/2012, the employer did not certify the complete abatement of the cited violation.
Recent events (1)
  • — Z (O) $400

1903.19 D01

Other-than-serious 6 instances 3 exposed
Issued
Nov 27, 2012
Abate by
Dec 30, 2012
Penalty
Initial $400 · Current $400
29 CFR 1903.19(d)(1):     The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.    a)  For Citation 1, item 1, issued on 10/19/2012 with an abatement date of 10/22/2012, the employer did not submit documents demonstrating complete abatement of the cited violation to OSHA.    b)  For Citation 2, item 1, issued on 10/19/2012 with an abatement date of 10/22/2012, the employer did not submit documents demonstrating complete abatement of the cited violation to OSHA.    c)  For Citation 2, item 2a, issued on 10/19/2012 with an abatement date of 10/22/2012, the employer did not submit documents demonstrating complete abatement of the cited violation to OSHA.    d)  For Citation 2, item 2b, issued on 10/19/2012 with an abatement date of 10/22/2012, the employer did not submit documents demonstrating complete abatement of the cited violation to OSHA.    e)  For Citation 2, item 2c, issued on 10/19/2012 with an abatement date of 10/22/2012, the employer did not submit documents demonstrating complete abatement of the cited violation to OSHA.    f)  For Citation 2, item 3, issued on 10/19/2012 with an abatement date of 10/22/2012, the employer did not submit documents demonstrating complete abatement of the cited violation to OSHA.
Recent events (1)
  • — Z (O) $400

1910.134 E01

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 19, 2012
Abate by
Oct 22, 2012
Penalty
Initial $3,080 · Current $3,080
29 CFR 1910.134(e)(1):  The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    Employees sandblasting and spray painting are required to wear a sandblasting hood and a tight-fitting, cartridge type, half mask respirator and exposed to respirator misuse and paint exposure hazards.  Medical evaluations prior to employee fit-testing were not completed.
Recent events (1)
  • — Z (S) $3080

1910.95 C01

Repeat Gravity 10 1 instance 1 exposed
Issued
Oct 19, 2012
Abate by
Oct 22, 2012
Penalty
Initial $5,600 · Current $5,600
29 CFR 1910.95(c)(1): A continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (n) was not instituted when employees noise exposures equaled or exceeded an 8 hour time-weighted average sound level (TWA) of 85 dBA:    An employee, performing abrasive blasting, was found to be in excess of the action level for noise and the employer had not implemented an effective hearing conservation program.    a. An employee was exposed to continuous and intermittent noise at 1265% of the action level or an equivalent sound level of approximately 108.3 dBA during the 282 minute sample period.    Steelcad Industrial Services, Inc was previously cited for a violation of this Occupational Safety and Health Standard, or its equivalent standard, 29 CFR 1910.95(c)(1), which was contained in OSHA Inspection Number 313018038,  Citation 1, Item 1, and was affirmed as a Final Order on June 10, 2011, with respect to a workplace located at 1270 Jamestown Road Cutler, IL 62238.
Recent events (1)
  • — Z (R) $5600

1910.106 D04 III

Repeat Gravity 10 1 instance 2 exposed
Issued
Oct 19, 2012
Abate by
Oct 22, 2012
Penalty
Initial $5,600 · Current $5,600
1910.106(d)(4)(iii) : Electrical wiring and equipment located in inside storage rooms used for Class I liquids were not approved under subpart S of this part for Class I, Division 2 Hazardous Locations.    Employees were exposed to possible burns while working in an approximately 30 foot long by 20 foot wide and 20 foot high storage room used to store flammable chemicals (Class I) such as Xylene.   The storage room did not have electrical lights, wiring and receptacles which was approved for Class I, Division 2 Hazardous Locations.    Steelcad Industrial Services, Inc was previously cited for a violation of this Occupational Safety and Health Standard, or its equivalent standard, 29 CFR 1910.106(d)(4)(iii), which was contained in OSHA Inspection Number 313018020,  Citation 1, Item 1a, and was affirmed as a Final Order on June 10, 2011, with respect to a workplace located at 1270 Jamestown Road Cutler, IL 62238.
Recent events (1)
  • — Z (R) $5600

1910.307 B

Repeat Gravity 10 1 instance 2 exposed
Issued
Oct 19, 2012
Abate by
Oct 22, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.307(b): All areas designated as hazardous (classified) locations under the Class and Zone system and areas designated under the Class and Division system established after August 13, 2007 were not properly documented. This documentation was not available to those authorized to design, install, inspect, maintain, or operate electric equipment at the location:     Employees were exposed to possible burns while working in paint room and a storage room used to apply and store flammable chemicals (Class I) such as Macropoxy 646, and Xylene.   The employer did not document such hazardous locations.    Steelcad Industrial Services, Inc was previously cited for a violation of this Occupational Safety and Health Standard, or its equivalent standard, 29 CFR 1910.307(b), which was contained in OSHA Inspection Number 313018020, Citation 1, Item 1b, and was affirmed as a Final Order on June 10, 2011, with respect to a workplace located at 1270 Jamestown Road Cutler, IL 62238.
Recent events (1)
  • — Z (R) $0

1910.307 C02 I

Repeat Gravity 10 1 instance 2 exposed
Issued
Oct 19, 2012
Abate by
Oct 22, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.307(c)(2)(i): Electrical installations were not approved for the class location, but also for the ignitable or combustible properties of the specific gas, vapor, dust, or fiber that was present.:       Employees were exposed to possible burns while working in paint room used to apply flammable chemicals (Class I) such as Macropoxy 646.   The storage room did not have electrical lights, wiring and receptacles which was approved for Class I, Division 2 Hazardous Locations.    Steelcad Industrial Services, Inc was previously cited for a violation of this Occupational Safety and Health Standard, or its equivalent standard, 29 CFR 1910.307(c)(2)(i), which was contained in OSHA Inspection Number 313018020,  Citation 1, Item 1c, and was affirmed as a Final Order on June 10, 2011, with respect to a workplace located at 1270 Jamestown Road Cutler, IL 62238.
Recent events (1)
  • — Z (R) $0

1910.106 D04 IV

Repeat Gravity 10 1 instance 2 exposed
Issued
Oct 19, 2012
Abate by
Oct 22, 2012
Penalty
Initial $5,600 · Current $5,600
29 CFR 1910.106(d)(4)(iv) : Every inside storage room was not provided with either a gravity or a mechanical exhaust ventilation system which provided for a complete change of air within the room at least six times per hour.     Employees were exposed to possible burns while working in an approximately 30 foot long by 10 foot wide and 20 foot high storage room used to store flammable chemicals such as Xylene.   The storage room did not have a working ventilation system or a gravity based ventilation system which provided for a complete change of air within the room at least six times per hour.    Steelcad Industrial Services, Inc was previously cited for a violation of this Occupational Safety and Health Standard, or its equivalent standard, 29 CFR 1910.106(d)(4)(iv), which was contained in OSHA Inspection Number 313018020,  Citation 1, Item 2, and was affirmed as a Final Order on June 10, 2011, with respect to a workplace located at 1270 Jamestown Road Cutler, IL 62238.
Recent events (1)
  • — Z (R) $5600

1910.253 B04 III

Other-than-serious 1 instance 5 exposed
Issued
Oct 19, 2012
Abate by
Oct 26, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials a minimum distance of 20 feet or by a non-combustible barrier at least 5 feet high having a fire-resistance rating of at least one-half hour:    Employees work in the area of compressed cylinder storage were exposed to fire hazards in that the barrier was 4.5 feet high and not mechanically secured between the fuel-gas and oxygen cylinders as to ensure a one-half hour fire rating.
Recent events (1)
  • — Z (O) $0

View Steelcad Industrial Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334097029.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.