Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CAMBARA CONSTRUCTION AND REMODELING

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CAMBARA CONSTRUCTION AND REMODELING in 2308 WHEATLAND CIRCLE, PITTSBURGH, PA 15268 (NAICS 238160). OSHA activity number 334101029.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cambara Construction and Remodeling — free Get an email when a new federal OSHA severe-injury report for Cambara Construction and Remodeling is published. One employer, no account, unsubscribe in one click.
Site address
2308 WHEATLAND CIRCLE
City
PITTSBURGH
State
PA
ZIP
15268
Mailing
512 LANCASTER PLACE, FREDERICK, MD 21703
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 6, 2012
Abate by
Jun 7, 2012
Penalty
Initial $2,800 · Current $2,112 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure:          a) Job site, 2308 Wheatland Circle, Pittsburgh, PA: On or about April 30, 2012, during roofing work on a residential home, the employer did not ensure that fall protection systems/devices were used where employees were exposed to falls of approximately 25 feet.
Recent events (2)
  • — I (S) $2112
  • — Z (S) $2800

1926.502 D16 II

Serious Gravity 5 1 exposed
Issued
Jun 6, 2012
Abate by
Jun 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(16)(ii): The employer did not ensure that the fall arrest system used limited the maximum arresting force on an employee to 1,800 pounds (8 KN) when used with a body harness:        a) Job site, 2308 Wheatland Circle, Pittsburgh, PA: On or about April 30, 2012, during roofing work on a residential home, the employer did not ensure that fall arrest systems limited the arresting force on the employee to 1,800 pounds. An employee was using a harness with a rope grab system and did not incorporate a shock absorbing lanyard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 D16 III

Serious Gravity 5 1 exposed
Issued
Jun 6, 2012
Abate by
Jun 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(16)(iii): Fall arrest systems were not rigged such that an employee could neither free fall more than 6 feet (1.8 m), nor contact any lower level:          a) Job site, 2308 Wheatland Circle, Pittsburgh, PA: On or about April 30, 2012, during roofing work on a residential home along the front of the house, the employer did not ensure that fall arrest systems limited free falls to 6 feet. A worker installing roofing materials was anchored to a tie off point approximately 15 feet from where he was working and could have fallen from the eave edge over 6 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 10 4 exposed
Issued
Jun 6, 2012
Abate by
Jun 7, 2012
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access; or, when such an extension was not possible because of the ladder's length, the ladder was not secured at its top to a rigid support that would not deflect, and a grasping device, such as a grabrail, was not provided to assist employees in mounting and dismounting the ladder:          a) Job site, 2308 Wheatland Circle, Pittsburgh, PA: On or about April 30, 2012, during roofing work on a residential home, the employer did not ensure that the ladder used for access to the roof/egress from the roof was properly set up in that it did not extend at least 3 feet above the landing surface.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

1926.1053 B16

Other-than-serious 4 exposed
Issued
Jun 6, 2012
Abate by
Jun 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not immediately marked in a manner that readily identifies them as defective, or be tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired:          a) Job site, 2308 Wheatland Circle, Pittsburgh, PA: On or about April 30, 2012, during roofing activities, the employer didn not ensure that the ladder used to gain access to/egress from from the roof was taken out of service when it had damaged areas. Rungs of the ladder were bent and/or torn.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Cambara Construction and Remodeling's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334101029.