CICERO, IL —
OSHA Inspection: MILAN'S MACHINING & MFG. CO., INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MILAN'S MACHINING & MFG. CO., INC. in 1301 S. LARAMIE AVE., CICERO, IL 60804 (NAICS 332721). OSHA activity number 334109220.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MILAN'S MACHINING & MFG. CO., INC.
- Site address
- 1301 S. LARAMIE AVE.
- City
- CICERO
- State
- IL
- ZIP
- 60804
- Mailing
- 1301 S. LARAMIE AVE., CICERO, IL 60804
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332721
- Employees
- 60
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Aug 6, 2012
- Abate by
- Oct 31, 2012
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by rotating moving parts. Shop area - On or about May 2, 2012, the rotating chucks on the following metal cutting lathes were not completely guarded, thereby exposing employees to the hazards of rotating moving parts. 1. Clausing 600. Clausing Colchester, Clausing Tur 630 2. LeBlond Regal 3. Tos Celakovice .
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.147 C06 I
- Issued
- Aug 6, 2012
- Abate by
- Sep 18, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. Shop area - On or about May 2, 2012, the employer did not conduct a periodic inspection of the energy control procedures at least annually to ensure that the proceduress and requirements of the standard were being followed.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Milan'S Machining & MFG. CO., INC.
View Milan'S Machining & MFG. CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332721)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334109220.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.