On , OSHA opened a complaint safety inspection of T & B TRANSPORTATION, INC. in 4938 SOUTHWAY ST. SW, CANTON, OH 44706 (NAICS 484110). OSHA activity number 334111242.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch T & B Transportation, INC. for free Get an email when a new federal OSHA severe-injury report for T & B Transportation, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4938 SOUTHWAY ST. SW
City
CANTON
State
OH
ZIP
44706
Mailing
4938 SOUTHWAY ST. SW, CANTON, OH 44706
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484110
Employees
23
Ownership type
Private (A)

12 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 15, 2012
Abate by
Oct 30, 2012
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:    On and before 5/2/2012, the employer was using the flat roof above the office and storage rooms in the repair shop as a material and parts storage area without a standard guardrail and toeboard. Employees are exposed to a fall hazard when accessing the flat roof to store and retrieve parts.
Recent events (2)
  • · I (S) $800
  • · Z (S) $1600

1910.37 A03

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 15, 2012
Penalty
Initial $1,020 · Current $510 Reduced
29 CFR 1910.37(a)(3): Exit routes were not free and/or unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route:    On 5/2/2012, the exit route and discharge at the east side of the building was blocked by shelving and material.
Recent events (2)
  • · I (S) $510
  • · Z (S) $1020

1910.37 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 15, 2012
Abate by
Oct 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":    On 5/2/2012, the west exit discharge door was not marked as an exit.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.157 C04

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 15, 2012
Penalty
Initial $1,020 · Current $510 Reduced
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition:    On 5/2/2012, the portable fire extinguisher mounted at west wall of the shop was not fully charged.
Recent events (2)
  • · I (S) $510
  • · Z (S) $1020

1910.157 E02

Serious 1 instance 3 exposed
Issued
Oct 15, 2012
Abate by
Oct 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:    On and before 5/2/2012, the portable fire extinguishers in the shop were not being inspected monthly.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.157 G01

Serious Gravity 1 1 instance 23 exposed
Issued
Oct 15, 2012
Abate by
Oct 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:    On and before 5/2/2012, the employees had not received portable fire extinguisher training.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 L01 I

Serious Gravity 5 1 instance 6 exposed
Issued
Oct 15, 2012
Abate by
Oct 30, 2012
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    On and before 5/2/2012, the forklift operators did not receive training and evaluation.
Recent events (2)
  • · I (S) $800
  • · Z (S) $1600

1910.178 Q07

Serious Gravity 1 1 instance 6 exposed
Issued
Oct 15, 2012
Abate by
Oct 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service, and shall not be placed in service if the examination shows any condition adversely affecting the safety of the vehicle. Such examination shall be made at least daily:    On and before 5/2/2012, the forklifts used for working on the trucks and moving around associated equipment and material were not inspected daily.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.303 G02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 15, 2012
Penalty
Initial $1,700 · Current $850 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    On 5/2/2012, the electrical distribution panel at the southeast corner of the building had live parts that were not protected by an approved enclosure.
Recent events (2)
  • · I (S) $850
  • · Z (S) $1700

1910.1200 E01

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 15, 2012
Abate by
Dec 31, 2012
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    On and before 5/2/2012, the employer did not have a hazard communication program for chemicals such as but not limited to tire mounting compound, battery cleaner and brakleen.
Recent events (2)
  • · I (S) $600
  • · Z (S) $1200

1910.101 A

Other-than-serious 1 instance 3 exposed
Issued
Oct 15, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.101(a): The employer did not determine that compressed gas cylinders under his control were in a safe condition to the extent that this could be determined by visual inspection:    On 5/2/2012, there were oxygen, propane and acetylene cylinders that were not properly secured for storage.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.305 B01 II

Other-than-serious 1 instance 3 exposed
Issued
Oct 15, 2012
Abate by
Oct 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    On 5/2/2012, there was an electrical junction box for a duplex receptacle at the west wall near the exit discharge door that had two unused openings in the cover plate.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0