On , OSHA opened a planned health inspection of INGRAM READY MIX, INC. in 1316 N. BOWIE, SEGUIN, TX 78155 (NAICS 327320). OSHA activity number 334120235.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ingram Ready MIX, INC. for free Get an email when a new federal OSHA severe-injury report for Ingram Ready MIX, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1316 N. BOWIE
City
SEGUIN
State
TX
ZIP
78155
Mailing
3880 FM 482, NEW BRAUNFELS, TX 78132
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327320
Employees
23
Ownership type
Private (A)

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 15, 2012
Abate by
Jun 29, 2012
Penalty
Initial $5,000 · Current $3,000 Reduced
OSH ACT of 1970 Section (5)(a)(1):     Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a fall hazard of approximately 9 feet 10 inches while welding on the top hatch of a tanker truck without fall protection.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that employees use fall protection while working at heights greater than four (4) feet.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $5000

1910.106 E02 IV A

Serious Gravity 1 3 instances 41 exposed
Issued
Jun 15, 2012
Abate by
Jun 29, 2012
Penalty
Initial $3,000 · Current $1,800 Reduced
29 CFR 1910.106(e)(2)(iv)(a):     Flammable liquids were uncovered when not in use:    On or about May 2, 2012, and at times prior thereto, two one-gallon containers of Rust-Oleum, and one one-gallon container of PRISM 3.5 VOC Acrylic Urethane stored in the flammable storge shed were not kept closed while not in use.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that flammable materials are kept sealed when not in use.
Recent events (2)
  • · I (S) $1800
  • · Z (S) $3000

1910.107 B05 I

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 15, 2012
Abate by
Jun 29, 2012
Penalty
Initial $3,000 · Current $1,800 Reduced
29 CFR 1910.107(b)(5)(i):     Visible gauges or audible alarm or pressure activated devices were not installed to indicate or insure that the required air velocity was maintained:    On or about May 2, 2012, and at times prior thereto, gauges or alarms were not installed in the paint booth to ensure the required air velocity was maintained in the areas to prevent build up of flammable vapors and paint overspray.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that air flow gauges or alarms are installed in the spray booth.
Recent events (2)
  • · I (S) $1800
  • · Z (S) $3000

1910.107 F01

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 15, 2012
Abate by
Jun 29, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.107(f)(1):     Sprinkler heads were not located so as to provide water distribution throughout the entire booth:    On or about May 2, 2012 and at times prior thereto, the employer did not ensure that sprinkler heads were installed in the spray booth.  The employer utilizes epoxy primer and urethane based paint which are Class 1A and 1C flammable liquids.     Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that sprinkler heads are installed in the spray booth.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.107 G07

Serious Gravity 1 2 instances 2 exposed
Issued
Jun 15, 2012
Abate by
Jun 29, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.107(g)(7):     "No smoking" signs in large letters on contrasting color background were not conspicuously posted at all spraying areas and paint storage rooms:    On or about May 2, 2012, and at times prior thereto, no smoking signs were not posted at the spray area or at the flammable storage shed.      Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that "no smoking" signs are posted at the spray booth and flammable storage shed.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.157 G02

Serious Gravity 1 1 instance 23 exposed
Issued
Jun 15, 2012
Abate by
Jun 29, 2012
Penalty
Initial $3,000 · Current $1,800 Reduced
29 CFR 1910.157(g)(2):     The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:    On or about May 2, 2012 and at times prior thereto, the employer did not provide annual fire extinguisher training to employees who may use the device to fight incipient stage fires.  The employers written fire extinguisher training plan gives the employees a choice to put out fires or leave the building.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that employees that are expected to fight fires are trained at least annually in the proper use of fire extinguishers.
Recent events (2)
  • · I (S) $1800
  • · Z (S) $3000

1910.157 C04

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 15, 2012
Abate by
Jun 29, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(4):     Portable fire extinguishers were not kept in their designated places at all times except during use:    On or about May 2, 2012, and at times prior thereto, one of the designated sites for a fire extinguisher in the spray booth was empty.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure fire extinguishers are kept in their designated places when not in use.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.106 E05 I

Serious Gravity 1 1 instance 23 exposed
Issued
Jun 15, 2012
Abate by
Jun 29, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(5)(i):     Portable fire extinguishment and control equipment was not provided in such quantities and types as were needed for special hazards of operation and storage:    On or about May 2, 2012, and at times prior there to, there was no fire extinguisher located at the flammable storage shed.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that a fire extinguisher is located at the flammable storage shed.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Ingram Ready MIX, INC.'s full OSHA safety record →