SUMMIT, IL —
OSHA Inspection: TRADE CONSTRUCTION CO.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of TRADE CONSTRUCTION CO. in 7322 W 61ST ST, SUMMIT, IL 60501 (NAICS 238390). OSHA activity number 334121027.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRADE CONSTRUCTION CO.
- Site address
- 7322 W 61ST ST
- City
- SUMMIT
- State
- IL
- ZIP
- 60501
- Mailing
- 9059 STRATFORD LANE, PALOS HILLS, IL 60465
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238390
- Employees
- 2
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.20 B01
- Issued
- May 9, 2012
- Abate by
- May 31, 2012
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.20(b)(1): It shall be the responsibility of the employer to initiate and maintain such programs as may benecessary to comply with this part. a. On or about May 2, 2011 - at the above addressed jobsite, the employer did not initiate an accident prevention program and/or safety and health program to comply with the regulations of this part which included, but were not limited to employee protection when exposed to electrical hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $1200
1926.403 I02 I
- Issued
- May 9, 2012
- Abate by
- May 10, 2012
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1926.403(i)(2)(i): Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means: a. On or about May 2, 2012 - at the above addressed jobsite, an employee installing door hardware as well as cleaning up the interior of the house, was working around electrical outlets that were not provided with covers or face plates to protect against accidental contact, thereby exposing the employee to electrical hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $1600
1926.405 A02 II B
- Issued
- May 9, 2012
- Abate by
- May 10, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(B): Branch circuits shall originate in a power outlet or panel board. Conductors shall be run as multi conductor cord or cable assemblies or open conductors, or shall be run in raceways. All conductors shall be protected by overcurrent devices at their capacity. Runs of open conductors shall be located where the conductors will not be subject to physical damage, and the conductors shall be fastened at intervals not exceeding 10 feet (3.05 m). No branch-circuit conductors shall be laid on the floor. Each branch circuit that supplies receptacles or fixed equipment shall contain a separate equipment grounding conductor if the branch circuit is run as open conductors. a. On or about May 2, 2012 - at the above addressed jobsite, an employee installing door hardware as well as cleaning up the interior of the house, was working around conductors that were not protected from physical damage, thereby exposing the employee to electrical shocks.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.405 A02 II E
- Issued
- May 9, 2012
- Abate by
- May 10, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(E): All lamps for general illumination shall be protected from accidental contact or breakage. Metal-case sockets shall be grounded. a. On or about May 2, 2012 - at the above addressed jobsite, an employee installing door hardware as well as cleaning up the interior of the house, was exposed to electrical hazards due to temporary lighting not being protected from accidental contact or breakage, thereby exposing the employee to hazards associated with electrical shocks.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections in this industry (NAICS 238390)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334121027.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.