GLOUCESTER CITY, NJ ·
OSHA Inspection: S. COWGILL ROOFING
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of S. COWGILL ROOFING in 500 JERSEY AVE, GLOUCESTER CITY, NJ 08030 (NAICS 238160). OSHA activity number 334125820.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- S. COWGILL ROOFING
- Site address
- 500 JERSEY AVE
- City
- GLOUCESTER CITY
- State
- NJ
- ZIP
- 08030
- Mailing
- 115 BARLOW AVE, GLOUCESTER CITY, NJ 08030
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.20 B02
- Issued
- May 25, 2012
- Abate by
- Jun 18, 2012
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.20(b)(2) The employer did not develop an accident prevention program, that provided for frequent and regular inspections of the job sites, materials, and equipment, to be made by competent persons designated by the employer. a) 500 Jersey Ave., Gloucester, NJ: Employee was exposed to fall hazards between 20 and 25 feet while conducting roofing work on the sloped (6 on 12 pitch) roof of a multistory commercial building. The employer had not initiated a program for a competent person to conduct frequent and regular inspections of the job site, to identify hazards and/or stop the work in the event workers were placed in a hazardous condition and as such the employee was not provided adequate fall protection (PFAS, safety nets, guardrails, etc.). Observed on or about 05/03/2012. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1926.503 A01
- Issued
- May 25, 2012
- Abate by
- Jun 18, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might was exposed to fall hazards that enabled the employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards. a) 500 Jersey Ave., Gloucester, NJ: Employee was exposed to fall hazards between 20 and 25 feet while conducting roofing work on the sloped (6 on 12 pitch) roof of a multistory commercial building with no fall protection. The employee had not been trained in the recognition of the hazards as well as the procedures to minimize those hazards when working from heights. Observed on or about 05/03/2012. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.501 B01
- Issued
- May 25, 2012
- Abate by
- May 29, 2012
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) 500 Jersey Ave., Gloucester, NJ: Employee was exposed to fall hazards between 20 and 25 feet while conducting roofing work on the sloped (6 on 12 pitch) roof of a multistory commercial building and was not provided adequate fall protection (PFAS, safety nets, guardrails, etc.). Observed on or about 05/03/2012. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.