Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: STOPA ROOFING INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of STOPA ROOFING INC. in 53 CHURCH STREET, WINDSOR LOCKS, CT 06096 (NAICS 238160). OSHA activity number 334126638.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stopa Roofing INC. for free Get an email when a new federal OSHA severe-injury report for Stopa Roofing INC. is published. One employer, no account, unsubscribe in one click.
Establishment
STOPA ROOFING INC.
Site address
53 CHURCH STREET
City
WINDSOR LOCKS
State
CT
ZIP
06096
Mailing
99 REAGAN ROAD, GRANVILLE, MA 01034
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

5 citations on file for this inspection.

1926.451 B05 II

Serious Gravity 10 1 instance 2 exposed
Issued
May 7, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.451(b)(5)(ii):     Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.      Worksite: Two employees were on a ladder jack scaffold about 17 feet off the ground, one side of the scaffold extended about 36 inches over its support. The platform was not secured to the jacks.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1926.451 F06

Serious Gravity 5 1 instance 2 exposed
Issued
May 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(6):  Scaffolds were not erected, used, dismantled, altered, or moved such that they or any conductive material handled on them would not come closer than 3 feet to exposed and energized power lines which were less than 300 volts.    Exception to paragraph (f)(6): Scaffolds and materials may be closer to power lines than specified above where such clearance is necessary for performance of work, and only after the utility company, or electrical system operator, has been notified of the need to work closer and the utility company, or electrical system operator, has deenergized the lines, relocated the lines, or installed protective coverings to prevent accidental contact with the lines.      Worksite: The ladder jack scaffold's platform was about 6 inches away from the 220 volts secondary lines entering a residential house
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 G01 I

Serious Gravity 10 3 instances 2 exposed
Issued
May 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1)(i):     Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold shall be protected by a personal fall arrest system;      Worksite: Two employees were utilizing a ladder jack scaffold 20 feet of the ground without utilizing personal fall protection equipment.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
May 7, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.501(b)(13):     Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b)  Note:  If using these systems was infeasible or created a greater hazard, the employer should develop and implement a fall protection plan meeting the requirements of paragraph (k) of 1926.502.    Worksite: Employees were engaged in roofing activities 22 feet above ground on an 10:12 pitch roof and 10 feet porch roof with a 3:12 pitch without utilizing any type of fall protection.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1926.1053 B01

Serious Gravity 5 2 instances 4 exposed
Issued
May 7, 2012
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.1053(b)(1):     Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:      Worksite: The side rails of the fiberglass extension ladder used to access the roof were not extended at least 3 feet above the landing.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334126638.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.