OSHA Inspection: BROTHERS PRINTING CO., INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BROTHERS PRINTING CO., INC. in 2000 EUCLID AVE, CLEVELAND, OH 44115 (NAICS 323110). OSHA activity number 334138450.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Brothers Printing CO., INC. — free Get an email when a new federal OSHA severe-injury report for Brothers Printing CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
2000 EUCLID AVE
City
CLEVELAND
State
OH
ZIP
44115
Mailing
2000 EUCLID AVE, CLEVELAND, OH 44115
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323110
Employees
10
Ownership type
A

8 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 26, 2012
Abate by
Sep 25, 2012
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    On and before 5/3/2012, the employer did not have a lockout tagout program that addresses service and maintenance of machinery onsite such as, but not limited to, nine printing presses and one shrink wrap machine.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.157 G01

Serious Gravity 1 1 instance 10 exposed
Issued
Jul 26, 2012
Abate by
Sep 25, 2012
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:    On and before 5/3/2012, the employer did not provide portable fire extinguisher training. The employees use a combustible liquid that releases vapors when heated above ambient temperatures that can cause a flash fire.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1910.178 L01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 26, 2012
Abate by
Sep 25, 2012
Penalty
Initial $1,600 · Current $600 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    On and before 5/3/2012, the forklift operator did not receive training and evaluation.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1600

1910.219 D01

Serious Gravity 5 2 instances 2 exposed
Issued
Jul 26, 2012
Abate by
Aug 10, 2012
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    On 5/3/2012, on the main floor in the printing room, the Chandler Price printing press and PAR air compressor had drive pulley and belt systems that were not guarded.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.303 G02 I

Serious Gravity 5 3 instances 3 exposed
Issued
Jul 26, 2012
Abate by
Aug 10, 2012
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    On 5/3/2012, the following electrical equipment had live parts that were not guarded against accidental contact.  a. The electrical service panel in the main printing room storage area had exposed knife switches and open fuses.  b. There was electrical conductor wiring in the main printing room storage area that was sticking out of the wall.   c. The Federal Pacific breaker box in the offset room had openings for overcurrent devices that were missing.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.305 B02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 26, 2012
Abate by
Jul 31, 2012
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:    On 5/3/2012, the electrical receptacle for the air conditioner at the back of the main printing room did not have a cover plate.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1910.178 Q07

Other-than-serious 1 instance 1 exposed
Issued
Jul 26, 2012
Abate by
Aug 10, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:    On and before 5/3/2012, the Kalmar forklift used in the binary department did not receive an inspection before being placed in service.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B01 II

Deleted Other-than-serious 1 instance 2 exposed
Issued
Jul 26, 2012
Abate by
Jul 31, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    On 5/3/2012, the electrical disconnect switch box on the wall behind the air compressor had an unused opening at the side.