Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: SHREVES ENGINE REBUILDING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SHREVES ENGINE REBUILDING in 3815 N. 21ST ST, SAINT LOUIS, MO 63107 (NAICS 336399). OSHA activity number 334153830.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Shreves Engine Rebuilding for free Get an email when a new federal OSHA severe-injury report for Shreves Engine Rebuilding is published. One employer, no account, unsubscribe in one click.
Site address
3815 N. 21ST ST
City
SAINT LOUIS
State
MO
ZIP
63107
Mailing
3815 N. 21ST ST, SAINT LOUIS, MO 63107
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
16
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 1 1 instance 13 exposed
Issued
May 25, 2012
Penalty
Initial $1,301 · Current $910 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:      1. In the machine shop area, employees were using a Bridgeport Drill Press with no arbor (chuck) guard in place over the drill bit.
Recent events (2)
  • · I (S) $910.35
  • · Z (S) $1300.5

1910.212 A05

Serious Gravity 1 1 instance 13 exposed
Issued
May 25, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(5):     Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:    1. In the production area, near the large bay door, employees were using a Maxx Air High Velocity 42 inch portable fan with a large unguarded opening (6" X 6") in the middle of the cover on the fan.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.303 G02 I

Serious Gravity 1 1 instance 13 exposed
Issued
May 25, 2012
Penalty
Initial $1,301 · Current $910 Reduced
29 CFR 1910.303(g)(2)(i):     Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):        1. In the machine shop, on the west wall, there was a live 120 volt wire protruding out of conduit exposed to employee contact. There was no junction box or other electrical installation connected to the conduit.
Recent events (2)
  • · I (S) $910.35
  • · Z (S) $1300.5

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334153830.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.