GLENMONT, NY —
OSHA Inspection: QED MECHANICAL AND CONSTRUCTION CORP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of QED MECHANICAL AND CONSTRUCTION CORP in 15 FRONTAGE ROAD, GLENMONT, NY 12077 (NAICS 238130). OSHA activity number 334161437.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QED MECHANICAL AND CONSTRUCTION CORP
- Site address
- 15 FRONTAGE ROAD
- City
- GLENMONT
- State
- NY
- ZIP
- 12077
- Mailing
- 14-25 140TH STREET, WHITESTONE, NY 11357
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 9
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.701 B
- Issued
- Jun 14, 2012
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: a) Econolodge Addition Main Entrance - On or about 4 May, 2012 - Employees entering and exiting the building addition were exposed to an impalement hazard when the 12 inch long 1/2 inch diameter reinforcing steel bar protruding up from the concrete was not guarded. Employees were exposed to an impalement hazard.
Recent events (1)
- — Z (S) $1600
1926.501 B14
- Issued
- Jun 14, 2012
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.501(b)(1): Each employee working on, at, above, or near wall openings where the outside bottom edge of the wall opening is 6 feet or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches above the walking/working surface, shall be protected from falling by the use of a guardrail systems, a safety net system, or a personal fall arrest system. a) Econolodge Addition Third Floor West Side - On or about 4 May, 2012 - Employees were doing cleanup and bringing in materials on the third floor of the new addition without any fall protection and were exposed to a fall hazard by an unguarded wall opening. Employees were exposed to a fall of 28 feet.
Recent events (1)
- — Z (S) $2000
1926.502 B03
- Issued
- Jun 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge: a) Econolodge Addition Third Floor Landing - On or about 4 May, 2012 - Employees accessing the third floor of the addition were exposed to a fall hazard when the top guardrail was not installed to withstand a lateral force of at least 200 pounds. Employees were exposed to a fall hazard of 10 feet.
Recent events (1)
- — Z (S) $0
1926.1052 C01 I
- Issued
- Jun 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) Econolodge Addition Stairwell from first to third floor - On or about 4 May, 2012 - Employees using the stairwell to travel between the third and first floors were exposed to a fall hazard because at least one handrail was not installed. Employees were exposed to a fall hazard of 10 feet between floors.
Recent events (1)
- — Z (S) $0
1926.404 B01 II
- Issued
- Jun 14, 2012
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection. a) Building Front - On or about 4 May, 2012 - Employees were framing out the extension walls and using an electric drill to drill holes for the anchor bolts. Employees were using an outlet that had a defective ground fault circuit interrupter. Employees were exposed to an electrocution hazard.
Recent events (1)
- — Z (S) $1200
More inspections in this industry (NAICS 238130)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334161437.