OSHA Inspection: QED MECHANICAL AND CONSTRUCTION CORP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of QED MECHANICAL AND CONSTRUCTION CORP in 15 FRONTAGE ROAD, GLENMONT, NY 12077 (NAICS 238130). OSHA activity number 334161437.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch QED Mechanical and Construction Corp — free Get an email when a new federal OSHA severe-injury report for QED Mechanical and Construction Corp is published. One employer, no account, unsubscribe in one click.
Site address
15 FRONTAGE ROAD
City
GLENMONT
State
NY
ZIP
12077
Mailing
14-25 140TH STREET, WHITESTONE, NY 11357
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
9
Ownership type
A

5 citations on file for this inspection.

1926.701 B

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 14, 2012
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement:    a) Econolodge Addition Main Entrance - On or about 4 May, 2012 - Employees entering and exiting the building addition were exposed to an impalement hazard when the 12 inch long 1/2 inch diameter reinforcing steel bar protruding up from the concrete was not guarded. Employees were exposed to an impalement hazard.
Recent events (1)
  • — Z (S) $1600

1926.501 B14

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 14, 2012
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.501(b)(1): Each employee working on, at, above, or near wall openings where the outside bottom edge of the wall opening is 6 feet or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches above the walking/working surface, shall be protected from falling by the use of a guardrail systems, a safety net system, or a personal fall arrest system.      a) Econolodge Addition Third Floor West Side - On or about 4 May, 2012 - Employees were doing cleanup and bringing in materials on the third floor of the new addition without any fall protection and were exposed to a fall hazard by an unguarded wall opening. Employees were exposed to a fall of 28 feet.
Recent events (1)
  • — Z (S) $2000

1926.502 B03

Serious Gravity 5 1 instance 6 exposed
Issued
Jun 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge:    a) Econolodge Addition Third Floor Landing - On or about 4 May, 2012 - Employees accessing the third floor of the addition were exposed to a fall hazard when the top guardrail was not installed to withstand a lateral force of at least 200 pounds. Employees were exposed to a fall hazard of 10 feet.
Recent events (1)
  • — Z (S) $0

1926.1052 C01 I

Serious Gravity 1 1 instance 5 exposed
Issued
Jun 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:    a) Econolodge Addition Stairwell from first to third floor - On or about 4 May, 2012 - Employees using the stairwell to travel between the third and first floors were exposed to a fall hazard because at least one handrail was not installed. Employees were exposed to a fall hazard of 10 feet between floors.
Recent events (1)
  • — Z (S) $0

1926.404 B01 II

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 14, 2012
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection.    a) Building Front - On or about 4 May, 2012 - Employees were framing out the extension walls and using an electric drill to drill holes for the anchor bolts. Employees were using an outlet that had a defective ground fault circuit interrupter. Employees were exposed to an electrocution hazard.
Recent events (1)
  • — Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334161437.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.