OSHA Inspection: FIRE & SAFETY SPECIALISTS, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of FIRE & SAFETY SPECIALISTS, INC. in 20000 STATE HIGHWAY 48 E, BROWNSVILLE, TX 78523 (NAICS 213112). OSHA activity number 334164027.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fire & Safety Specialists, INC. — free Get an email when a new federal OSHA severe-injury report for Fire & Safety Specialists, INC. is published. One employer, no account, unsubscribe in one click.
Site address
20000 STATE HIGHWAY 48 E
City
BROWNSVILLE
State
TX
ZIP
78523
Mailing
7701 JOHNSTON STREET, MAURICE, LA 70555
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
3
Ownership type
A

4 citations on file for this inspection.

1915.12 F

Other-than-serious 7 exposed
Issued
Oct 24, 2012
Abate by
Nov 15, 2012
Penalty
Initial $7,000 · Current $1,500 Reduced
29 CFR 1915.12(f):     Each employer whose employees work in confined and enclosed spaces or other dangerous atmospheres did not ensure all available information on the hazards, safety rules, and emergency procedures concerning those spaces and atmospheres was exchanged with any other employer whose employees may enter the same spaces:    In the water maker room, on the vessel Noble Sam Noble, located on the floating dry dock of AmFELS, LLC, employees were conducting service and testing on the twenty-six bottle carbon dioxide fire suppression system.  The employer failed to notify all employees working in adjacent rooms or areas of potential hazards including but not limited to release of carbon dioxide, oxygen deficient atmosphere and asphyxiation.
Recent events (3)
  • — F (O) $1500
  • — C (S) $7000
  • — Z (S) $7000

1915.89 L03 II

Other-than-serious 1 instance 7 exposed
Issued
Oct 24, 2012
Abate by
Nov 15, 2012
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1915.89(l)(3)(ii):     The contract employer did not ensure the host employer knew about the lockout/tags-plus hazards associated with the contract employer's work and what the contract employer was doing to address these hazards:    In the water maker room on the vessel Noble Sam Noble, located on the floating dry dock of Keppel AmFELS, LLC, contract employees were assigned to service and test the twenty-six bottle carbon dioxide fire suppression system.  Prior to the servicing and maintenance on the system, Fire & Safety Specialists, Inc. did not inform the host employer that the fire suppression system had not been locked out and that the manual activation bar at the top of the two pilot cylinders of Carbon Dioxide had been removed disabling the time delay siren, alarm and pressure switches.
Recent events (3)
  • — F (O) $0
  • — C (S) $7000
  • — Z (S) $7000

1915.89 L03 I

Other-than-serious 1 instance 7 exposed
Issued
Oct 24, 2012
Abate by
Nov 15, 2012
Penalty
Initial $7,000 · Current $1,500 Reduced
29 CFR 1915.89(l)(3)(i):     The contract employer did not follow the host employer's lockout/tags-plus program and procedures:    In the water maker room on the vessel Noble Sam Noble, located on the floating dry dock of AmFELS, LLC, employees were servicing and testing the twenty-six bottle carbon dioxide fire suppression system.  Fire & Safety Specialists, Inc. did not ensure its employees conducting the servicing and testing followed the host employer's lockout/tags plus program and procedures as outlined in the "Isolations" section of the Noble Safety Policy Manual.
Recent events (3)
  • — F (O) $1500
  • — C (S) $7000
  • — Z (S) $7000

1915.506 F

Serious Gravity 10 7 exposed
Issued
Oct 24, 2012
Abate by
Nov 15, 2012
Penalty
Initial $7,000 · Current $5,000 Reduced
29 CFR 1915.506(f):     Before conducting maintenance on a fixed extinguishing system, the employer did not ensure the system was physically isolated.    In the water maker room on the vessel Noble Sam Noble, located on the floating dry dock of Keppel AmFELS, LLC, employees were assigned to service and test the twenty-six bottle carbon dioxide fire suppression system.  The employer did not ensure a means to isolate the system from the protected areas during the servicing and/or maintenance was provided and used.
Recent events (3)
  • — F (S) $5000
  • — C (S) $7000
  • — Z (S) $7000