Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: GSI DIVERSIFIED

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GSI DIVERSIFIED in 7208A WEIL AVE., SAINT LOUIS, MO 63119 (NAICS 326299). OSHA activity number 334174448.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch GSI Diversified — free Get an email when a new federal OSHA severe-injury report for GSI Diversified is published. One employer, no account, unsubscribe in one click.
Establishment
GSI DIVERSIFIED
Site address
7208A WEIL AVE.
City
SAINT LOUIS
State
MO
ZIP
63119
Mailing
7208A WEIL AVE., SAINT LOUIS, MO 63119
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326299
Employees
25
Ownership type
A

7 citations on file for this inspection.

1910.217 C02 I A

Serious Gravity 5 1 instance 5 exposed
Issued
May 24, 2012
Penalty
Initial $2,975 · Current $2,083 Reduced
29 CFR 1910.217(c)(2)(i)(a):     Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s)      a. Examples existed of power presses operated without side guards.
Recent events (2)
  • — I (S) $2082.5
  • — Z (S) $2975

1910.217 C02 III

Serious Gravity 5 1 instance 5 exposed
Issued
May 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.217(c)(2)(iii):     Fixed barrier guard(s) on mechanical power press(es) were not attached securely to the frame of the press or to the bolster plate:    a. Examples existed of movable plexiglass panels not securely attached to the expanded metal guard in front of power presses; the panel could be swung from side to side in order to gain unimpeded access to the point of operation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 B02

Serious Gravity 5 1 instance 5 exposed
Issued
May 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.219(b)(2):     Crank(s) or connecting rod(s) exposed to contact were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o) or by guardrail(s) as described in CFR 1910.219(o)(5)      a. The metal arm and disc crank to power press #10 were not guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 G05

Serious Gravity 1 1 instance 2 exposed
Issued
May 24, 2012
Penalty
Initial $2,100 · Current $1,470 Reduced
29 CFR 1910.304(g)(5):     The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    a. Examples existed of missing ground pins or bypassed ground pins, such as to the Delta 6" disc sander where the ground pin on the power cord was used (and bypassed) when plugged into a two wire extension cord; and a missing pin on a 110 V fan.
Recent events (2)
  • — I (S) $1470
  • — Z (S) $2100

1910.305 G01 IV A

Serious Gravity 1 1 instance 1 exposed
Issued
May 24, 2012
Abate by
Jul 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A):     Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    a. Permanent wiring (outlet) was not provided for energization of the Custom Cutter; an extension cord was used to power the equipment.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.95 G06

Other-than-serious 1 instance 5 exposed
Issued
May 24, 2012
Abate by
Jul 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.95(g)(6):     At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels :    a. Annual audiograms had been discontinued (note: along with annual hearing tests, annual training on enforcement and the correct use of hearing protection is required).    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C06 I

Other-than-serious 1 instance 2 exposed
Issued
May 24, 2012
Abate by
Jul 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i):     The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    a. Where equipment was maintained, adjusted, and repaired, requiring lockout, an annual inspection/audit had not been conducted for over a year in order to determine that lockout was being performed as required, that all specific operating procedures were written and up to date, that employees were trained as authorized or affected employees, and that training was certified.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334174448.