SAINT LOUIS, MO —
OSHA Inspection: GSI DIVERSIFIED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GSI DIVERSIFIED in 7208A WEIL AVE., SAINT LOUIS, MO 63119 (NAICS 326299). OSHA activity number 334174448.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GSI DIVERSIFIED
- Site address
- 7208A WEIL AVE.
- City
- SAINT LOUIS
- State
- MO
- ZIP
- 63119
- Mailing
- 7208A WEIL AVE., SAINT LOUIS, MO 63119
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326299
- Employees
- 25
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.217 C02 I A
- Issued
- May 24, 2012
- Penalty
- Initial $2,975 · Current $2,083 Reduced
General-duty citation text
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s) a. Examples existed of power presses operated without side guards.
Recent events (2)
- — I (S) $2082.5
- — Z (S) $2975
1910.217 C02 III
- Issued
- May 24, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(c)(2)(iii): Fixed barrier guard(s) on mechanical power press(es) were not attached securely to the frame of the press or to the bolster plate: a. Examples existed of movable plexiglass panels not securely attached to the expanded metal guard in front of power presses; the panel could be swung from side to side in order to gain unimpeded access to the point of operation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 B02
- Issued
- May 24, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(b)(2): Crank(s) or connecting rod(s) exposed to contact were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o) or by guardrail(s) as described in CFR 1910.219(o)(5) a. The metal arm and disc crank to power press #10 were not guarded.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.304 G05
- Issued
- May 24, 2012
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a. Examples existed of missing ground pins or bypassed ground pins, such as to the Delta 6" disc sander where the ground pin on the power cord was used (and bypassed) when plugged into a two wire extension cord; and a missing pin on a 110 V fan.
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1910.305 G01 IV A
- Issued
- May 24, 2012
- Abate by
- Jul 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a. Permanent wiring (outlet) was not provided for energization of the Custom Cutter; an extension cord was used to power the equipment. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.95 G06
- Issued
- May 24, 2012
- Abate by
- Jul 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels : a. Annual audiograms had been discontinued (note: along with annual hearing tests, annual training on enforcement and the correct use of hearing protection is required). Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C06 I
- Issued
- May 24, 2012
- Abate by
- Jul 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a. Where equipment was maintained, adjusted, and repaired, requiring lockout, an annual inspection/audit had not been conducted for over a year in order to determine that lockout was being performed as required, that all specific operating procedures were written and up to date, that employees were trained as authorized or affected employees, and that training was certified. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 326299)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334174448.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.