FORT OGLETHORPE, GA —
OSHA Inspection: HITSON CABINET DESIGNS, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of HITSON CABINET DESIGNS, INC. in 1452 CROSS STREET, FORT OGLETHORPE, GA 30742 (NAICS 337110). OSHA activity number 334176633.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HITSON CABINET DESIGNS, INC.
- Site address
- 1452 CROSS STREET
- City
- FORT OGLETHORPE
- State
- GA
- ZIP
- 30742
- Mailing
- 1452 CROSS STREET, FORT OGLETHORPE, GA 30742
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 12
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 II
- Issued
- Aug 17, 2012
- Abate by
- Sep 10, 2012
- Penalty
- Initial $2,000 · Current $800 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the techniques to be utilized for the control of hazardous energy, including, but not limited to items of this section: a) Shop - LOTO procedures for equipment such as SCMI Superset XL CNC, Quick Wood System Elite 1400 and Boring System 46, lacked elements such as machine shut down, the application of lock out/tag out devices and verification of isolation.
Recent events (2)
- — I (S) $800
- — Z (S) $2000
1910.147 C06 I
- Issued
- Aug 17, 2012
- Abate by
- Sep 10, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a) Shop - The documented LOTO procedures for the computerized numerical control machines, sanders and boring machines had not been inspected within approximately the last 2 years.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A02 II
- Issued
- Aug 17, 2012
- Abate by
- Sep 10, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): Portable cord and plug-connected equipment with defect or evidence of damage was not removed from service: a) Shop - The employer failed to remove a 10" Rigid miter saw from service that had a damaged power cord.
Recent events (1)
- — Z (O) $0
More inspections at Hitson Cabinet Designs, INC.
View Hitson Cabinet Designs, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334176633.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.