Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: EI DUPONT AND DE NEMOURS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of EI DUPONT AND DE NEMOURS in 2551 BUFFALO ROAD, NIAGARA FALLS, NY 14302 (NAICS 325188). OSHA activity number 334187432.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch EI Dupont and DE Nemours for free Get an email when a new federal OSHA severe-injury report for EI Dupont and DE Nemours is published. One employer, no account, unsubscribe in one click.
Site address
2551 BUFFALO ROAD
City
NIAGARA FALLS
State
NY
ZIP
14302
Mailing
2551 BUFFALO ROAD, NIAGARA FALLS, NY 14302
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325188
Employees
192
Ownership type
A

3 citations on file for this inspection.

1910.179 G01 IV

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 19, 2012
Penalty
Initial $6,000 · Current $4,500 Reduced
29 CFR 1910.179(g)(1)(iv):     Where multiple conductor cable is used with a suspended pushbutton station, the station must be supported in some satisfactory manner that will protect the electrical conductors against strain.    a) On or about 05/07/12 in the 12 Shop; the north pendant strain relief was separated from the pendant body, wrapped with white tape and the insulated conductors at the top opening of the pendant body were clearly visible.      No Abatement Certification
Recent events (2)
  • · I (S) $4500
  • · Z (S) $6000

1910.179 G02 II

Serious 4 exposed
Issued
Jul 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.179(g)(2)(ii):     Electric equipment shall be protected from dirt, grease, oil, and moisture.    a) On or about 05/07/12 in the 12 Shop; the strain relief on the north pendant for the overhead crane was pulled away from the pendant body and wrapped with white tape exposing the inside of the pendant body to environmental conditions.        No Abatement Certification
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.179 G03 VII

Serious Gravity 5 4 exposed
Issued
Jul 19, 2012
Penalty
Initial $6,000 · Current $4,500 Reduced
29 CFR 1910.179(g)(3)(vii):     Pushbuttons in pendant stations shall return to the "off" position when pressure is released by the crane operator.    a) On or about 4/26/12 in the 12 Shop; after being used, the north pendant for the overhead crane ( Harnischfeger - CH3287 6 ton capacity ) did not return to the off position allowing the block and hook ( 300# ) to lower itself to the floor.      No Abatement Certification
Recent events (2)
  • · I (S) $4500
  • · Z (S) $6000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334187432.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.