PEARSALL, TX —
OSHA Inspection: SCORPION EXPLORATION & PRODUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SCORPION EXPLORATION & PRODUCTION, INC. in WILLIAMS #2 WELL 15 MI EAST, 4 MI SOUTH, 2 MI EAST, 1/2 MI NORTH TO LOCATION, PEARSALL, TX 78061 (NAICS 213111). OSHA activity number 334217841.
Where did this inspection happen?
- Establishment
- SCORPION EXPLORATION & PRODUCTION, INC.
- Site address
- WILLIAMS #2 WELL 15 MI EAST, 4 MI SOUTH, 2 MI EAST, 1/2 MI NORTH TO LOCATION
- City
- PEARSALL
- State
- TX
- ZIP
- 78061
- Mailing
- PO BOX 643, BENAVIDES, TX 78341
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- Employees
- 12
- Ownership type
- A
Citations
18 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $2070.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees working from the derrick board, in case of an emergency, are exposed to having a means of egress blocked: The rig derrick: On or about May 7, 2012, and at times prior thereto, employees had drilled an oil/gas well and were rigging down (disassembling) the drilling rig. Those employees working on the derrick racking board were not provided with a secondary means of egress. This exposed those employees to the hazard of a blowout, and/or fire and explosion. The American Petroleum Institute Recommended Practices for Occupational Safety for Oil and Gas Well Drilling and Servicing Operations, RP 54, 6.10.1, requires that an auxiliary means of escape be installed on rig mast/derricks and that it provides a ready and convenient means of escape from the derrickman's working platform.
Recent events (2)
- — I (S) $2070
- — Z (S) $4900
1910.22 C
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.22(c): Covers and/or guardrails were not provided to protect personnel from the hazards of open pits, tanks, vats, ditches, etc. a) West side of drilling rig, southern mud pit: On or about May 7, 2012, and at times prior thereto, employees were exposed to a fall into mud pits filled with drilling mud and drilling debris, while working with and around the pits. b) West side of the drilling rig, middle mud/sand pit: On or about May 7, 2012, and at times prior thereto, employees were exposed to a fall into to mud pits filled with drilling mud and drilling debris, while working with and around the pits. c) West side of the drilling rig, northern mud pit: On or about May 7, 2012, and at times prior thereto, employees were exposed to a fall into mud pits filled with drilling mud and drilling debris, while working with and around the pits.
Recent events (2)
- — I (S) $0
- — Z (S) $2100
1910.27 D01 II
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $2061.00 Reduced
General-duty citation text
29 CFR 1910.27(d)(1)(ii): Cages or wells (except as provided in subparagraph (5) of this paragraph) conforming to the dimensions shown in figures D-7, D-8, and D-9 were not provided on ladders of more than 20 feet to a maximum unbroken length of 30 feet: Rig #1 derrick: On or about May 7, 2012, and at times prior thereto, employees were exposed to a fall of 50 ft. in height to the drill floor below while using the derrick mounted ladder, that was not in a well or caged, to access the derrick.
Recent events (2)
- — I (S) $2061
- — Z (S) $4900
1910.106 B01 III A
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2061.00 Reduced
General-duty citation text
29 CFR 1910.106(b)(1)(iii)(a): Atmospheric tanks for flammable and combustible liquid use were not built in accordance with acceptable good standards of design and in accordance with the consensus standards contained in 1910.106(b)(1)(iii)(a)(1) through 1910.106(b)(1)(iii)(a)(3) that were incorporated by reference as specified in Sec. 1910.6: East side of the light house trailer: On or about May 7, 2012, and at times prior thereto, employees were exposed to a fire hazard when running the rig's diesel engine from an 800 gallon fiberglass tank that was not made for combustible liquid.
Recent events (2)
- — I (S) $2061
- — Z (S) $2800
1910.1200 F05
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein: East side of the light house: On or about May 7, 2012, and at times prior thereto, employees were exposed to a fire hazard from an 800 gallon tank containing diesel fuel, used to power a diesel engine, that was unmarked as to its content and the hazards associated with diesel fuel.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.141 C01 III
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2061.00 Reduced
General-duty citation text
29 CFR 1910.141(c)(1)(iii): The sewage disposal method endangered the health of the employee(s): East side of the well site temporary quarters: On or about May 7, 2012, and at times prior thereto employees were exposed to diseases such as but not limited to ecoli from unsanitary conditions resulting from a disconnected sewage pipe running from the main bunk into a ditch exposing human liquid and solid fecal matter.
Recent events (2)
- — I (S) $2061
- — Z (S) $2800
1910.142 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.142(c)(1): The water supplied to a temporary labor camp site for drinking, cooking, bathing, and laundry purposes had not been approved by the appropriate health authority: East side of the well site: On or about May 7, 2012, and at times prior thereto employees were exposed to diseases such as but not limited to ecoli when bathing, and cooking with non-potable water that was run through the drilling rigs water system while staying at temporay quarters in support of the rigging down (disassemble) of an oil/gas well.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.142 B08
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2061.00 Reduced
General-duty citation text
29 CFR 1910.142(b)(8): Exterior openings of temporary labor camp shelter(s) were not effectively screened with 16-mesh material: East side of the well site, on site living quarters: On or about May 7, 2012, and at times prior thereto employees were exposed to pest borne diseases such as but not limited to West Nile Virus from doorways that were not screened.
Recent events (2)
- — I (S) $2061
- — Z (S) $2800
1910.142 B10
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2061.00 Reduced
General-duty citation text
29 CFR 1910.142(b)(10): In temporary labor camps where cooking facilities were used in common, sanitary facilities were not provided for storing and preparing food: East side of the well site: On or about May 7, 2012, employees were exposed to unsanitary conditions from dirt, grime and litter present on the kitchen foor and throughout, while preparing and consuming food, and staying at temporary quarters in support of the disassembly of an oil/gas well.
Recent events (2)
- — I (S) $2061
- — Z (S) $2800
1910.142 D10
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.142(d)(10): Temporary labor campsite privies and toilet rooms were not kept in a sanitary condition and cleaned at least daily: a) East side of the well site, on site living quarters: On or about May 7, 2012, and at times prior thereto employees were exposed to the hazard of disease from dirt, grime and litter covering the lavatory. b) East side of the well site, on site living quarters: On or about May 7, 2012, and at times prior thereto employees were exposed to the hazard of disease from dirt, grime and litter covering the shower. c) East side of the well site, on site living quarters: On or about May 7, 2012, and at times prior thereto employees were exposed to the hazard of disease from dirt, grime and litter covering the water closet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.184 C14
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2061.00 Reduced
General-duty citation text
29 CFR 1910.184(c)(14): The employer used slings without affixed and legible identification markings: a) Drill floor: On or about May 7, 2012, and at times prior thereto employees were exposed to a struck by hazard from using approximately a 3/8" thick by 25' length steel chain sling to lift steel drill pipe measuring approximately 31' in length by 4.5" diameter from the catwalk into the mouse hole. b) Drill floor: On or about May 7, 2012, and at times prior thereto employees were exposed to a struck by hazard from using approximately a 3/8" thick by 25' length steel chain sling to lift the mouse hole from its operational position. c) Well site: On or about May 7, 2012, employees were exposed to a struck by hazard from using approximately a 1/4" by 10' in length steel chain attached to backhoe on one end and the other end attached to approximately a 9/16" thick by 15' in length wire rope sling that was in turn attached to a mud hopper and used to lift the hopper onto a transport trailer. d) Well site north east corner: On or about May 7, 2012, employees were exposed to a struck by hazard from using approximately a 1/4" by 10' in length steel chain attached to a backhoe on one end and the other end attached to approximately a 9/16" thick by 15' in length wire rope sling wire rope sling to lift a ground pipe anchor out of the ground.
Recent events (2)
- — I (S) $2061
- — Z (S) $2800
1910.184 E03 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.184(e)(3)(ii): Records of the most recent month in which each alloy steel chain sling was thoroughly inspected were not available for examination: a) Drill floor: On or about May 7, 2012, and at times prior thereto employees were exposed to a struck by hazard from using approximately a 3/8" thick by 25' length steel chain sling to lift steel drill pipe measuring approximately 31' in length by 4.5" diameter from the catwalk into the mouse hole. b) Drill floor: On or about May 7, 2012, and at times prior thereto employees were exposed to a struck by hazard from using approximately a 3/8" thick by 25' length steel chain sling to lift the mouse hole from its operational position. c) Well site: On or about May 7, 2012, employees were exposed to a struck by hazard from using approximately a 1/4" by 10' in length steel chain attached to backhoe on one end and the other end attached to approximately a 9/16" thick by 15' in length wire rope sling that was in turn attached to a mud hopper and used to lift the hopper onto a transport trailer. d) Well site north east corner: On or about May 7, 2012, employees were exposed to a struck by hazard from using approximately a 1/4" by 10' in length steel chain attached to a backhoe on one end and the other end attached to approximately a 9/16" thick by 15' in length wire rope sling wire rope sling to lift a ground pipe anchor out of the ground.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.304 F01 IV
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2061.00 Reduced
General-duty citation text
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel: Kitchen room of the bunk house/temporary living quarters: On or about May 7, 2012, and at times prior thereto, in case of an emergency, employees were exposed to an electrical shock from not being able to access a circuit breaker box located behind a refrigerator.
Recent events (2)
- — I (S) $2061
- — Z (S) $2800
1910.304 G01 IV
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2061.00 Reduced
General-duty citation text
29 CFR 1910.304(g)(1)(iv): AC systems of 50 volts to 1000 volts were not grounded under any of the conditions listed in subparagraphs (A)-(D): a) Light house: On or about May 7, 2012, employees were exposed to an electrical shock from a 125 kW diesel electrical generator that was not connected to an earth ground while the employees engaged in the drilling and rigging down of an oil/gas well. b) Light house: On or about May 7, 2012, employees were exposed to an electrical shock from a 75 kW diesel electrical generator that was not connected to an earth ground while the employees engaged in the drilling and rigging down of an oil/gas well.
Recent events (2)
- — I (S) $2061
- — Z (S) $3500
1910.305 A02 X
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2061.00 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points: a) Well site: On or about May 7, 2012, and at times prior thereto, employees were exposed to an electrical shock from electrical cordsets, connected to 120/240 V, circuits that were run across the ground exposed to vehicular traffic between the light plant and the bunk house while disassembling an oil/gas well. b) Well site: On or about May 7, 2012, and at times prior thereto, employees were exposed to an electrical shock from electrical cordsets, connected to 120/240 V, that were run across the ground exposed to vehicular traffic between the light plant and the tool pusher trailer while disassembling an oil/gas well.
Recent events (2)
- — I (S) $2061
- — Z (S) $3500
1910.305 B02 I
- Issued
- Abate by
- Penalty
- Initial $4200.00 · Current $2061.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) Bunk house/living quarters above the stove: On or about May 7, 2012, employees were exposed to an electrical shock from a 120 V wall mounted electrical receptacles that were missing face plates while employees engaged in disassembly of an oil/gas well. b) Bunk house/living quarters south sleeping room south wall: On or about May 7, 2012, employees were exposed to an electrical shock from a 120 V wall mounted electrical receptacles that were missing face plates while employees engaged in disassembly of an oil/gas well.
Recent events (2)
- — I (S) $2061
- — Z (S) $4200
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Bunk house, back wall of kitchen area, On or about May 7, 2012, and at times prior thereto employees were exposed to an electrical shock of 120 V from a black electrical cord running along the back wall and terminating in a circuit breaker box behind the refrigerator, while employees were in the process of disassembling and oil/gas well. b) Bunk house, back wall of kitchen area, On or about May 7, 2012, and at times prior thereto employees were exposed to an electrical shock of 120 V from an orange electrical cord running used to pug in a refrigerator while employees were in the process of disassembling and oil/gas well. c) Bunk house, south bedroom south wall, On or about May 7, 2012, and at times prior thereto employees were exposed to an electrical shock of 120 V from a electrical a black SEOOW 16-3 cable used to connect an uncovered electrical outlet to a circuit breaker box next to where employees slept. d) Bunk house, south bedroom south wall, On or about May 7, 2012, and at times prior thereto employees were exposed to an electrical shock of 120 V from a black electrical cord connected to a circuit breaker and running up into the ceiling next to where employees slept.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: Bunk house, south sleeping room: On or about May 7, 2012, and at times prior thereto employees were exposed to an electrical shock of 120 V from a SEOOW 16-3 cable used to connect an electrical wall outlet to a circuit breaker immediately adjacent to where the employees slept.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 213111)
JAL, NM—2026-07-01
HELMERICH & PAYNE, IDC
LAREDO, TX—2026-06-28
AXIS ENERGY SERVICES
MCALESTER, OK—2026-06-18
SANGUINE GAS EXPLORATION, LLC
MOUNT PLEASANT, MI—2026-06-15
BIGARD & HUGGARD DRILLING INC
MOUNT PLEASANT, MI—2026-06-15
BIGARD & HUGGARD DRILLING INC
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334217841.