Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: PROLERIZED NEW ENGLAND, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PROLERIZED NEW ENGLAND, INC. in 69 ROVER STREET, EVERETT, MA 02149 (NAICS 423930). OSHA activity number 334223831.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Prolerized NEW England, INC. — free Get an email when a new federal OSHA severe-injury report for Prolerized NEW England, INC. is published. One employer, no account, unsubscribe in one click.
Site address
69 ROVER STREET
City
EVERETT
State
MA
ZIP
02149
Mailing
69 ROVER STREET, EVERETT, MA 02149
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
110
Ownership type
A

3 citations on file for this inspection.

1910.23 E01

Serious Gravity 5 1 instance 5 exposed
Issued
Jul 2, 2012
Penalty
Initial $4,000 · Current $2,500 Reduced
29 CFR 1910.23(e)(1):     The railing did not have a vertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level and the intermediate rail was not approximately halfway between the top rail and the floor, platform, runway, or ramp:    (a) Location - Shaker East:  On or about 5/9/12, the top rail measured 30 inches to the floor of the platform.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4000

1910.147 C04 II

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 2, 2012
Abate by
Jul 31, 2012
Penalty
Initial $35,000 · Current $7,000 Reduced
29 CFR 1910.147(c)(4)(ii):     The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:    (a) Location - Shaker 2 East:  On or about 5/1/2012, the employer's energy control procedure for the vibrating pan conveyor did not contain steps for isolation and blocking kinetic energy to protect employees performing service/maintenance on the Marsh mallow springs.    Prolerized New England was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(4)(ii), which was contained in OSHA inspection number 315871921, citaiton 2, item  number 1 and was affirmed as a final order on 1/26/2012, with respect to a workplace located at 69 Rover Street, Everett, MA.
Recent events (2)
  • — I (S) $7000
  • — Z (R) $35000

1910.23 A08 II

Other-than-serious 1 instance 3 exposed
Issued
Jul 2, 2012
Penalty
Initial $850 · Current $600 Reduced
29 CFR 1910.23(a)(8)(ii):     Every floor hole into which persons could accidentally walk was not guarded by a floor hole cover of standard strength and construction:    (a) Location - Shaker East:  On or about 5/9/12, the platform walkway to access the vibrating conveyor contained a floor hole.