Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: M.W. ROOFING AND ALUMINIUM INCORPORATED

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of M.W. ROOFING AND ALUMINIUM INCORPORATED in 7853 MASON AVE, BURBANK, IL 60459 (NAICS 238160). OSHA activity number 334240447.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M.W. Roofing and Aluminium Incorporated — free Get an email when a new federal OSHA severe-injury report for M.W. Roofing and Aluminium Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
7853 MASON AVE
City
BURBANK
State
IL
ZIP
60459
Mailing
5509 W 85TH ST, BURBANK, IL 60459
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
May 22, 2012
Abate by
May 23, 2012
Penalty
Initial $2,800 · Current $1,380 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure.     a.  On or about May 9, 2012 - at the above addressed jobsite, employees performing roofing operations approximately twelve (12) feet five (5) inches above ground were not protected from falls, thereby exposing employees to fall hazards.
Recent events (2)
  • — I (S) $1380
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 10 1 instance 2 exposed
Issued
May 22, 2012
Abate by
May 23, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(1):  When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.    a.  On or about May 9, 2012 - at the above addressed jobsite, the portable ladder used to access the roof did not extend at least three (3) feet above the upper landing surface.  Employees were thereby exposed to the hazards associated with falls.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View M.W. Roofing and Aluminium Incorporated's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334240447.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.