SCHAUMBURG, IL ·
OSHA Inspection: CAREY'S HEATING AND AIR CONDITIONING, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of CAREY'S HEATING AND AIR CONDITIONING, INC. in 250 E. GOLF ROAD, SCHAUMBURG, IL 60173 (NAICS 238220). OSHA activity number 334243680.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CAREY'S HEATING AND AIR CONDITIONING, INC.
- Site address
- 250 E. GOLF ROAD
- City
- SCHAUMBURG
- State
- IL
- ZIP
- 60173
- Mailing
- 8201 W. 183RD STREET, UNIT B, TINLEY PARK, IL 60487
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 20
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.332 B01
- Issued
- Aug 6, 2012
- Abate by
- Aug 27, 2012
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 29 CFR 1910.331 through 1910.335 that pertained to their respective job assignments: a) The employer failed to ensure the employee exposed to electrical hazards while performing work on or near live electrical parts were trained in and familiar with safety related work practices required by 29 CFR 1910.331 through 1910.335.
Recent events (1)
- · Z (S) $2000
1910.333 A02
- Issued
- Aug 6, 2012
- Abate by
- Aug 27, 2012
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.333(a)(2): Where exposed live parts were not de-energized, other safety-related work practices were not used to protect employees who could be exposed to the electrical hazards involved: a) Technicians working on or near live electrical parts did not use safety related work practices.
Recent events (1)
- · Z (S) $2800
1910.335 A01 I
- Issued
- Aug 6, 2012
- Abate by
- Aug 27, 2012
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with, and did not use, electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed: a) Technical employee working on or near live electrical parts such as the Lennox air conditioning unit model #GCS24-813-78-2G, serial #5698C 00574, did not use electrical protective equipment such as volt rated gloves, and fire retardant clothing.
Recent events (1)
- · Z (S) $2800
1910.335 A01 V
- Issued
- Aug 6, 2012
- Abate by
- Aug 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(v): Employees exposed to the danger of injury to the eyes or face from electric arcs or flahes or from flying objects resulting from electrical explosion did not wear protective equipment for the eyes or face: a) Technical employees working on or near live electrical parts such as the Lennox air conditioning unit model #GCS24-813-78-2G, serial #5698C 00574, did not use eyes or face protection. Employees were exposed to the danger of injury to the eyes or face from electric arcs, flashes and from objects.
Recent events (1)
- · Z (S) $0
1910.335 A01 IV
- Issued
- Aug 6, 2012
- Abate by
- Aug 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(iv): Employees exposed to the danger head injury from electric shock or burns due to contact with exposed energized parts did not wear nonconductive head protection: a) Technical employee working on or near live electrial parts such as the Lennox air conditioning unit model #GCS24-813-78-2G, serial #5698C 00574, did not use nonconductive head protection. Employees were exposed to the danger of head injury and burns.
Recent events (1)
- · Z (S) $0
More inspections at Carey'S Heating and AIR Conditioning, INC.
View Carey'S Heating and AIR Conditioning, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334243680.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.