Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: BEAUMONT METAL INDUSTRIES INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BEAUMONT METAL INDUSTRIES INC. in 3115 MILAM, BEAUMONT, TX 77701 (NAICS 332999). OSHA activity number 334247319.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Beaumont Metal Industries INC. for free Get an email when a new federal OSHA severe-injury report for Beaumont Metal Industries INC. is published. One employer, no account, unsubscribe in one click.
Site address
3115 MILAM
City
BEAUMONT
State
TX
ZIP
77701
Mailing
3115 MILAM, BEAUMONT, TX 77701
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
7
Ownership type
A

4 citations on file for this inspection.

1910.215 A04

Serious Gravity 5 2 instances 1 exposed
Issued
May 25, 2012
Abate by
May 26, 2012
Penalty
Initial $1,500 · Current $900 Reduced
29 CFR 1910.215(a)(4):     Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    (a)  At the worksite near the welders shop, on May 10, 2012, the left work rest for the Dayton Electric bench grinder (model 2LKR6) was adjusted approximately 1/2 inch away from the grinding wheel.  This condition exposed employees to struck-by hazards.    (b)  At the worksite near the welders shop, on May 10, 2012, the right work rest for the Dayton Electric bench grinder (model 2LKR6) was adjusted approximately 1/2 inch away from the grinding wheel.  This condition exposed employees to struck-by hazards.
Recent events (2)
  • · I (S) $900
  • · Z (S) $1500

1910.215 B09

Serious Gravity 5 2 instances 1 exposed
Issued
May 25, 2012
Abate by
May 26, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9):     The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    At the worksite near welders shop, on May 10, 2012, the left tongue guard for the Dayton Electric (model 2LKR6) was adjusted approximately 1 away from the grinding wheel.  This condition exposed employees to struck-by hazards.    At the worksite near welders shop, on May 10, 2012, the right tongue guard for the Dayton Electric (model 2LKR6) was adjusted approximately 1 away from the grinding wheel.  This condition exposed employees to struck-by hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.219 D01

Serious Gravity 5 2 instances 2 exposed
Issued
May 25, 2012
Abate by
Jun 4, 2012
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.219(d)(1):     Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    (a)  At the worksite in the middle of the facility, on May 10, 2012, the pulley for the large Lockforming 'roll forming' machine was not equipped with a guard.  This condition exposed employees to caught-by hazards.      (b)  At the worksite in the middle of the facility, on May 10, 2012, the pulley for the small Lockforming 'roll forming' machine was not equipped with a guard.  This condition exposed employees to caught-by hazards.
Recent events (2)
  • · I (S) $720
  • · Z (S) $1200

1910.305 G01 IV A

Serious Gravity 5 6 instances 4 exposed
Issued
May 25, 2012
Abate by
Jun 4, 2012
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.305(g)(1)(iv)(A):     Flexible cords and cables were used as a substitute for the fixed wiring of a structure:    At the worksite, on May 10, 2012, the 4 hanging fluorescent lighting fixtures were wired with flexible cords.    At the worksite, on May 10, 2012, 2 flexible cords were hanging from the ceiling and used as a power source for employees.
Recent events (2)
  • · I (S) $720
  • · Z (S) $1200

View Beaumont Metal Industries INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334247319.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.