Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PRECISION PLASTERING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PRECISION PLASTERING in 4370 EAST LUCAS, BEAUMONT, TX 77708 (NAICS 238140). OSHA activity number 334249364.

Watch Precision Plastering — free Get an email when a new federal OSHA severe-injury report for Precision Plastering is published. One employer, no account, unsubscribe in one click.
Site address
4370 EAST LUCAS
City
BEAUMONT
State
TX
ZIP
77708
Mailing
9555 BROUN STREET, BEAUMONT, TX 77707
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 22, 2012
Abate by
Jun 23, 2012
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.451(b)(1):     Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):    At the south section of the worksite, on May 10, 2012, an employee was installing molding to the exterior of the  building from the second level of the scaffold.  The 3.5 feet wide level was equipped with 3 planks measuring approximately 9.5 inches wide, leaving a gap of approximately 13.5 inches.  This condition exposed employees to a fall of approximately 6 feet.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.451 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 22, 2012
Abate by
Jun 23, 2012
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.451(e)(1):     When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.    At the worksite, on May 10, 2012, an employee was installing exterior molding to the building from the second level of the scaffold had to use the cross bracing and vertical member for access and egress.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.451 G01 VII

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 22, 2012
Abate by
Jun 23, 2012
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1926.451(g)(1)(vii):     Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    At the worksite, on May 10, 2012, an employee was installing exterior molding to the southwest portion of the building from the second level of the fabricated frame scaffolding.  The employee was not protected against falls of approximately 12 feet.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

View Precision Plastering's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334249364.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.