BEAUMONT, TX —
OSHA Inspection: PRECISION PLASTERING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PRECISION PLASTERING in 4370 EAST LUCAS, BEAUMONT, TX 77708 (NAICS 238140). OSHA activity number 334249364.
Where did this inspection happen?
- Establishment
- PRECISION PLASTERING
- Site address
- 4370 EAST LUCAS
- City
- BEAUMONT
- State
- TX
- ZIP
- 77708
- Mailing
- 9555 BROUN STREET, BEAUMONT, TX 77707
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B01
- Issued
- Jun 22, 2012
- Abate by
- Jun 23, 2012
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): At the south section of the worksite, on May 10, 2012, an employee was installing molding to the exterior of the building from the second level of the scaffold. The 3.5 feet wide level was equipped with 3 planks measuring approximately 9.5 inches wide, leaving a gap of approximately 13.5 inches. This condition exposed employees to a fall of approximately 6 feet.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.451 E01
- Issued
- Jun 22, 2012
- Abate by
- Jun 23, 2012
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. At the worksite, on May 10, 2012, an employee was installing exterior molding to the building from the second level of the scaffold had to use the cross bracing and vertical member for access and egress.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.451 G01 VII
- Issued
- Jun 22, 2012
- Abate by
- Jun 23, 2012
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. At the worksite, on May 10, 2012, an employee was installing exterior molding to the southwest portion of the building from the second level of the fabricated frame scaffolding. The employee was not protected against falls of approximately 12 feet.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
More inspections at Precision Plastering
View Precision Plastering's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334249364.