PEMBROKE, MA —
OSHA Inspection: YANKEE TRADER SEAFOOD LIMITED
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of YANKEE TRADER SEAFOOD LIMITED in 1610 CORPORATE PARK, PEMBROKE, MA 02359 (NAICS 311712). OSHA activity number 334281722.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- YANKEE TRADER SEAFOOD LIMITED
- Site address
- 1610 CORPORATE PARK
- City
- PEMBROKE
- State
- MA
- ZIP
- 02359
- Mailing
- 1610 CORPORATE PARK, PEMBROKE, MA 02359
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311712
- Employees
- 40
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.133 A01
- Issued
- Aug 14, 2012
- Abate by
- Sep 13, 2012
- Penalty
- Initial $2,380 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: Production Floor: Employer did not provide and require the use of eye protection for employees who handle corrosive materials for sanitation such as sodium hypochlorite (bleach), oven cleaner, Swisher Ultra Degreaser, acid sanitizer and Virkon Disinfectant/Virucide.
Recent events (2)
- — I (S) $1190
- — Z (S) $2380
1910.138 B
- Issued
- Aug 14, 2012
- Abate by
- Sep 13, 2012
- Penalty
- Initial $2,380 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.138(b): The employer did not base selection of appropriate hand protection on an evaluation of the performance characteristics of the hand protection relative to the task(s) to be performed, conditions present, duration of use, and the hazards and potential hazards identified: Production Floor: Employees who handle corrosive materials for sanitation such as sodium hypochlorite (bleach), oven cleaner, Swisher Ultra Degreaser, acid sanitizer, and Virkon Disinfectant/Virucide and hazardous materials for sanitation such as all-purpose cleaner, Wallop degreasing detergent, and Swisher Heavy-Duty Pot & Pan cleaner.
Recent events (2)
- — I (S) $1190
- — Z (S) $2380
1910.147 C04 I
- Issued
- Aug 14, 2012
- Abate by
- Sep 26, 2012
- Penalty
- Initial $2,380 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Establishment: Lock out tag out procedures had not been developed and implemented for de-energizing machines such as the Carton Sealer Machine.
Recent events (2)
- — I (S) $1190
- — Z (S) $2380
1910.303 G02 I
- Issued
- Aug 14, 2012
- Abate by
- Sep 26, 2012
- Penalty
- Initial $2,380 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): Establishment: The following electrical parts were not effectively closed: a) Shipping/Receiving Area: A junction box that energized the cooler/condenser unit was located in the wall adjacent to a bay door was damaged. b) Main Hallway to Production Area: A receptacle that energized the sump pump used to pump water out of the seafood bins was not effectively closed.
Recent events (2)
- — I (S) $1190
- — Z (S) $2380
1910.303 G02 II
- Issued
- Aug 14, 2012
- Abate by
- Sep 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(ii): In locations where electric equipment was likely to be exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage: Shipping/Receiving Area: A junction box that was located in the wall adjacent to a bay door was damaged.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L06
- Issued
- Aug 14, 2012
- Abate by
- Sep 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required by this paragraph (l) The employer did not certify employees who operate powered pallet jacks.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Yankee Trader Seafood Limited
View Yankee Trader Seafood Limited's full OSHA safety record →
More inspections in this industry (NAICS 311712)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334281722.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.