WASHINGTON, DC —
OSHA Inspection: J PARK, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of J PARK, INC. in 1310 G ST., NW, WASHINGTON, DC 20005 (NAICS 812930). OSHA activity number 334284932.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J PARK, INC.
- Site address
- 1310 G ST., NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20005
- Mailing
- 1310 G ST., NW, WASHINGTON, DC 20005
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 812930
- Employees
- 10
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.68 E01
- Issued
- Jun 26, 2012
- Abate by
- Jul 11, 2012
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1910.68(e)(1): All manlifts were not inspected by a designated competent person at intervals of not more than 30 days: Manlift, Ground Level - A Humphrey manlift, (serial no. A3422-9) was not inspected at least every thirty (30) days by a competent person for hazards, including, but not limited to, worn gears that might case the lift's endless belt to skip, on or about 05/01/2011.
Recent events (1)
- — Z (S) $2400
1910.68 B06 II
- Issued
- Jun 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.68(b)(6)(ii): The landing space adjacent to the floor openings was not free from obstruction and not kept clear at all times: a) Manlift, Ground Level - Employees were exposed to a struck-by hazards from: (1) a box; (2) an old cash register; (3) two brooms; and (4) a portable heater that were located between 16 and 18 inches of the unguarded floor opening through which the endless belt of a manlift passed during operation.
Recent events (1)
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Jun 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure: Manlift, Ground Level - A 14 gauge extension cord was used to power a refrigerator in the work area and was used in lieu of a permanent branch circuit, on or about 05/01/2012.
Recent events (1)
- — Z (O) $0
More inspections at J Park, INC.
View J Park, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 812930)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334284932.