ALBANY, NY —
OSHA Inspection: MOULTON MASONRY & CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MOULTON MASONRY & CONSTRUCTION in 1741 WESTERN AVE., ALBANY, NY 12203 (NAICS 238140). OSHA activity number 334287919.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MOULTON MASONRY & CONSTRUCTION
- Site address
- 1741 WESTERN AVE.
- City
- ALBANY
- State
- NY
- ZIP
- 12203
- Mailing
- 102 HOMER DRIVE, LAKE LUZERNE, NY 12846
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 5
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.25 A
- Issued
- Sep 5, 2012
- Abate by
- Sep 12, 2012
- Penalty
- Initial $1,320 · Current $1,320
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, form or scrap lumber with protruding nails was not kept clear from work areas: a) 1741 Western Ave. Albany, NY- On or about 5/11/12- Masonry employees were exposed to foot puncture hazards from protuding nails on scrap lumber.
Recent events (1)
- — Z (S) $1320
1926.451 B01
- Issued
- Sep 5, 2012
- Abate by
- Sep 12, 2012
- Penalty
- Initial $2,200 · Current $2,200
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) 1741 Western Ave. Albany, NY- On or about 5/11/12- Masonry foreman was exposed to a fall hazard of approximately (19') nineteen feet to ground level when performing masonry work from prefabricated frame scaffolding that was not fully planked. b) 1741 Western Ave. Albany, NY- On or about 5/11/12- Masonry foreman was exposed to a fall hazard of approximately (13') thirteen feet to ground level when performing masonry work from prefabricated frame scaffolding that was not fully planked.
Recent events (1)
- — Z (S) $2200
1926.451 C01
- Issued
- Sep 5, 2012
- Abate by
- Sep 12, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph. a) 1741 Western Ave. Albany, NY- On or about 5/11/12- Masonry foreman was exposed to a fall hazard of approximately (19') nineteen feet to ground level when performing masonry work from prefabricated frame scaffolding four tiers high that was not tied into the building to prevent tipping.
Recent events (1)
- — Z (S) $0
1926.451 C02 I
- Issued
- Sep 5, 2012
- Abate by
- Sep 12, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid and capable of supporting the loaded scaffold without settling or displacement: a) a) 1741 Western Ave. Albany, NY- On or about 5/11/12- Masonry foreman was exposed to a fall hazard of approximately (19') nineteen feet to ground level when performing masonry work from a prefabricated frame scaffolding that was positioned on uneven footings.
Recent events (1)
- — Z (S) $0
1926.451 E01
- Issued
- Sep 5, 2012
- Abate by
- Sep 12, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) 1741 Western Ave. Albany, NY- On or about 5/11/12- Masonry foreman was exposed to a fall hazard of approximately (19') nineteen feet to ground level when accessing a scaffolding that was not equipped with a ladder for access.
Recent events (1)
- — Z (S) $0
1926.451 G01 VII
- Issued
- Sep 5, 2012
- Abate by
- Sep 12, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) 1741 Western Ave. Albany, NY- On or about 5/11/12- Masonry foreman was exposed to a fall hazard of approximately (19') nineteen feet to ground level when performing masonry work from prefabricated frame scaffolding missing end and mid-guard railing.
Recent events (1)
- — Z (S) $0
1926.452 C04
- Issued
- Sep 5, 2012
- Abate by
- Sep 12, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(c)(4): End frames of tubular welded frame scaffolding were not locked together vertically by use of pins or equivalent means in areas where uplift could occur: a) 1741 Western Ave. Albany, NY- On or about 5/11/12- Masonry foreman was exposed to a fall hazard of approximately (19') nineteen feet to ground level when performing masonry work from prefabricated frame scaffolding not equipped with coupler pins.
Recent events (1)
- — Z (S) $0
1926.454 A
- Issued
- Sep 5, 2012
- Abate by
- Sep 12, 2012
- Penalty
- Initial $2,200 · Current $2,200
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) 1741 Western Ave. Albany, NY- On or about 5/11/12- For all employees performing masonry work from prefabricated frame scaffolding; employees were not trained to recognize hazards associated with improperly erected scaffolding.
Recent events (1)
- — Z (S) $2200
More inspections at Moulton Masonry & Construction
View Moulton Masonry & Construction's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334287919.