MCADOO, PA —
OSHA Inspection: ABC ROOFING
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ABC ROOFING in 223 SOUTH KENNEDY DRIVE, MCADOO, PA 18237 (NAICS 238160). OSHA activity number 334327111.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ABC ROOFING
- Site address
- 223 SOUTH KENNEDY DRIVE
- City
- MCADOO
- State
- PA
- ZIP
- 18237
- Mailing
- 143 W GRANT STREET, MCADOO, PA 18237
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- No inspection (D)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.307 D01
- Issued
- Nov 8, 2012
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.307(d)(1): Pulley(s) with part(s) seven feet (2.128 m) or less from the floor or work platform were not guarded in accordance with the requirements specified in paragraphs (m) and (o) of this section:Note: Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than 6 ft. 6 in. (1.976 m) from the floor or platform may be guarded with a disk covering the spokes. a) 223 S. Kennedy Dr. Mcadoo, PA 18237; While employees were operating a Lesson Power Ladder to send 80 pound shingle bundles to the roof area they were exposed to unguarded pulleys, on or about 06/14/12. Abatement Observed During Inspection - No Abatement Certification Required
Recent events (1)
- — Z (S) $1600
1926.307 E01 I
- Issued
- Nov 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.307(e)(1)(i): Horizontal belts which had both runs 7 feet (2.128 m) or less from the floor level were not guarded with a guard that extended to at least 15 inches (38.1 cm) above the belt or to a standard height specified in Table O-12: a) 223 S. Kennedy Dr. Mcadoo, PA 18237; While employees were operating a Lesson Power Ladder to send 80 pound shingle bundles to the roof area they were exposed to unguarded belts, on or about 06/14/12. Abatement Observed During Inspection - No Abatement Certification Required
Recent events (1)
- — Z (S) $0
1926.501 B11
- Issued
- Nov 8, 2012
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems. a) 223 S. Kennedy Dr. Mcadoo, PA 18237 / Small South Side Roof Area; While workers were working in this area without the use of fall protection they were exposed to an 8 foot 3 inch fall on a 7/12 pitch roof, on or about 06/14/12. b) 223 S. Kennedy Dr. Mcadoo, PA 18237 / Large South Side Roof Area; While workers were working in this area without the use of fall protection they were exposed to an 16 foot fall on a 6/12 pitch roof, on or about 06/14/12. c) 223 S. Kennedy Dr. Mcadoo, PA 18237 / Large North Side Roof Area; While workers were working in this area without the use of fall protection they were exposed to an 20 foot 7 inch fall on a 6/12 pitch roof, on or about 06/14/12. Abatement Observed During Inspection - No Abatement Certification Required
Recent events (1)
- — Z (S) $2000
1926.1053 B01
- Issued
- Nov 8, 2012
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder(s) length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigied support that will not deflect, and/or a grasping device was not provided to assist emmployees in mounting and dismounting the ladder. a) 223 S. Kennedy Dr. Mcadoo, PA / South Side Roof Area; Workers were using a Werner 20 foot extension ladder that was not 3 feet above the landing to access the 8 foot 3 inch high roof area, on or about 06/14/12. Abatement Observed During Inspection - No Abatement Certification Required
Recent events (1)
- — Z (S) $1200
1926.503 A01
- Issued
- Nov 8, 2012
- Abate by
- Nov 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) 223 S. Kennedy Dr. Mcadoo, PA 18237; Workers were working on roofs ranging in heights from 8 foot 3 inches to 20 feet 7 inches without fall hazard awareness training, on or about 06/14/12. Abatement Certification Required
Recent events (1)
- — Z (O) $0
1926.1060 A
- Issued
- Nov 8, 2012
- Abate by
- Nov 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. a) 223 S. Kennedy Dr. Mcadoo, PA 18237; Workers were using ladders in order to access work areas on the job site without a ladder hazard awareness training, on or about 06/14/12. Abatement Certification Required
Recent events (1)
- — Z (O) $0
More inspections at ABC Roofing
View ABC Roofing's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334327111.